{"product_id":"transistor-output-module-yokogawa-f3yd64-1p-k2","title":"Transistor Output Module Yokogawa F3YD64-1P\/K2","description":"\u003cp\u003eConfigured for high-density digital signal switching in FA-M3 control networks, the \u003cstrong\u003eYokogawa F3YD64-1P\/K2\u003c\/strong\u003e (\u003cstrong\u003eF3YD64-1P\/K2\u003c\/strong\u003e Transistor Output Module) provides direct electrical execution for 64-channel field device actuation via transistor sink-type outputs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P\/K2 defines a high-capacity output module within the FA-M3 architecture. The \"\/K2\" designation signifies a specific terminal interface arrangement, facilitating streamlined wiring for multi-channel systems while maintaining the standard 64-point transistor output matrix.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD64-1P\/K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.89 cm (W) x 8.32 cm (D) x 10 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e275 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS and Process Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P\/K2 facilitates robust switching for industrial process control loops. The module architecture employs photocoupler isolation to ensure signal integrity and electrical safety, providing 1500 V AC withstanding voltage between external connection terminals and the internal logic circuitry.\u003c\/p\u003e\n\u003cp\u003eThe 8-point-per-common grouping enables precise segmentation of field power, allowing for individual control loops to maintain channel-to-channel isolation effectiveness. This prevents cumulative noise interference and protects the central processor from load-side transients in complex FA-M3 automation environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module compatible with inductive loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided that a flyback diode is installed in parallel with the load. Since this is a transistor-based sink output module, back-EMF suppression is required to prevent permanent damage to the output transistors when switching solenoids, relays, or other inductive devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can the common lines be bridged for higher current capacity?\u003c\/p\u003e\n\u003cp\u003eA: No. The common lines are physically segmented into 8-point groups to maintain internal thermal and current limits. Do not attempt to parallel outputs or commons to exceed the 0.4 A-per-common limit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the system is powered down before inserting the module into the FA-M3 base unit to protect the backplane pins from electrical arcing.\u003c\/li\u003e\n\u003cli\u003eEnsure the two 40-pin connectors are fully seated and locked; utilize strain relief to prevent mechanical stress on the connector housing.\u003c\/li\u003e\n\u003cli\u003eKeep output wiring strictly separated from high-voltage AC cables to avoid induced noise on the switching signals.\u003c\/li\u003e\n\u003cli\u003eVerify the external 12 to 24 V DC power supply is properly regulated and connected to the correct terminals on the module.\u003c\/li\u003e\n\u003cli\u003eUse the onboard LED indicators to confirm output states during commissioning; if an LED is active but the device is not, inspect the field-side circuit for open-loop or load-side faults.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49243216281852,"sku":"F3YD64-1P\/K2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3YD64-1PK2.jpg?v=1782956035","url":"https:\/\/www.electronicplc.com\/products\/transistor-output-module-yokogawa-f3yd64-1p-k2","provider":"Electronic PLC","version":"1.0","type":"link"}