{"product_id":"tsxdet3242-schneider-electric-plc-discrete-input-module","title":"TSXDET3242 Schneider Electric PLC Discrete Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXDET3242\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input module for the Schneider Electric\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 independent input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor interfacing with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC field sensors, limit switches, and pushbuttons\u003c\/strong\u003e, maximizing I\/O capacity in a single Premium rack slot. This makes it ideal for large-scale manufacturing, infrastructure, and industrial automation applications.\u003c\/p\u003e\n\u003cp\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopto-isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect internal PLC logic from voltage spikes and electrical noise. High-speed signal processing with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadjustable input filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures accurate detection of fast pulses while suppressing false triggers from contact bounce. Its rugged design supports continuous 24\/7 industrial operation, maintaining signal integrity across a broad operating temperature range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete \/ Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Limits\u003c\/td\u003e\n\u003ctd\u003e19–30 V DC (at 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA per channel (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filtering\u003c\/td\u003e\n\u003ctd\u003eConfigurable 0.1 ms to 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms (Between inputs and ground\/logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e32 Front-panel LEDs (Channel state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Interface\u003c\/td\u003e\n\u003ctd\u003eDual HE10 connectors (Requires external cables\/terminal blocks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Connectivity\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Premium TSX RKY backplane\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHE10 connectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einstead of faceplate screw terminals for high-density wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTelefast pre-assembled cabling systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reduce wiring errors and assembly time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC external power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the field device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TSXDET3242 require an external power supply?\u003c\/strong\u003e\u003cbr\u003eYes. Each field sensor must be powered externally with 24 V DC. The module reads the voltage presence\/absence to determine the logical input state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a channel failure?\u003c\/strong\u003e\u003cbr\u003eUse the module's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRun\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFault LEDs\u003c\/strong\u003e. If a channel LED is off but voltage is present at the field terminal, inspect the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHE10 connector seating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the internal opto-isolator for potential faults.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48746794844412,"sku":"TSXDET3242","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/TSXDET3242_37180e8e-c884-42e5-885f-29cb8d6a23a0.jpg?v=1771055433","url":"https:\/\/www.electronicplc.com\/products\/tsxdet3242-schneider-electric-plc-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}