{"product_id":"versamax-ic200chs111-ge-fanuc-interposing-i-o-main-base","title":"GE Fanuc IC200CHS111 Versamax Interposing I\/O Main Base","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200CHS111 is a Versamax series interposing I\/O main base designed to provide robust electrical isolation between field devices and control system electronics. This module features 16 isolated channels, ensuring that high-voltage field signals do not compromise the integrity of the PLC backplane. By facilitating point-to-point galvanic isolation, the IC200CHS111 protects sensitive control hardware from voltage surges, cross-channel interference, and ground loops in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Isolation:\u003c\/strong\u003e Provides independent galvanic separation for each of the 16 I\/O points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Termination:\u003c\/strong\u003e Equipped with 50 box-style terminal blocks to support secure, vibration-resistant field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Includes 16 integrated LEDs for real-time status monitoring of individual channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Input:\u003c\/strong\u003e Features specific terminals (A17 and A18) for 24 VDC logic power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Engineered for reliable operation in high-stress environments, including chemical processing and power generation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Isolated Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Carry Current\u003c\/td\u003e\n\u003ctd\u003e8.0 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e8 A at 250 VAC \/ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e6 A at 250 VAC \/ 4 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e380 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Power\u003c\/td\u003e\n\u003ctd\u003e2000 VA (AC) \/ 240 W (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect power from the I\/O base and associated field devices before installing or removing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the base is securely mounted to the DIN rail or backplane to maintain proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for field connections to minimize EMI. Ensure all terminal screws are tightened to the specified torque to prevent loose connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain adequate ventilation around the module to ensure operating temperatures remain within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use appropriate electrostatic discharge (ESD) precautions when handling the module to prevent damage to internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC200CHS111?\u003c\/strong\u003e\u003cbr\u003eIt acts as an interposing base to provide galvanic isolation between field-side signals and the control system, protecting the PLC from electrical faults.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module handle AC and DC loads?\u003c\/strong\u003e\u003cbr\u003eYes, it is rated for both AC and DC switching, with specific limits for resistive and inductive loads as detailed in the technical specifications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I monitor the status of the channels?\u003c\/strong\u003e\u003cbr\u003eThe module features 16 individual LEDs on the front panel that provide visual feedback for each channel's switching state.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51006457479420,"sku":"IC200CHS111","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_19b1a930-1aea-4fbe-a102-41c11a958556.jpg?v=1787509954","url":"https:\/\/www.electronicplc.com\/products\/versamax-ic200chs111-ge-fanuc-interposing-i-o-main-base","provider":"Electronic PLC","version":"1.0","type":"link"}