{"product_id":"woodward-8200-1203-linknet-ht-analog-i-o-module","title":"Woodward 8200-1203 LinkNet HT Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-1203\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8200-1203\u003c\/strong\u003e Analog I\/O Module, operates as a dedicated hardware component for process parameter monitoring and current loop signal conditioning within LinkNet HT turbine and engine control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 450.8px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 35.4753%; height: 19.6px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 60.9831%; height: 19.6px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e8200-1203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e2.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e100 mm x 90 mm x 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e100 mA maximum (24 VDC supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eLinkNet HT Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 39.2px;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 39.2px;\"\u003e8 channels (4-20 mA, 250 ohm input impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 39.2px;\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 39.2px;\"\u003e2 channels (4-20 mA, 0-600 ohm load resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 39.2px;\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 39.2px;\"\u003e+\/-0.1 percent of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 39.2px;\"\u003eIntegrated Loop Power\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 39.2px;\"\u003e24 VDC (100 mA maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 39.2px;\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 39.2px;\"\u003eCANopen (up to 1 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eM12 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eDIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.4753%; height: 19.6px;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 60.9831%; height: 19.6px;\"\u003e0 to 95 percent RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermal Heat Sink Dissipation \u0026amp; Actuator Loop Feedback\u003c\/h3\u003e\n\u003cp\u003eInternal DC power conversion and active current loop driver circuitry generate heat managed through natural air convection across the compact enclosure housing. Efficient thermal heat sink dissipation preserves linear measurement accuracy (+\/-0.1 percent of span) under wide ambient temperature fluctuations from -40 to +70 deg C. Deterministic CANopen bus transmission speeds up to 1 Mbit\/s minimize signal transport latencies, maintaining rapid actuator loop feedback response for dynamic valve positioning and sensor monitoring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What cable specifications and connector types apply to the CANopen network bus?\u003c\/li\u003e\n\u003cli\u003eA: Communication requires shielded twisted-pair cabling terminated with M12 industrial connectors, with standard 120 ohm bus termination resistors installed at both physical ends of the CAN network.\u003c\/li\u003e\n\u003cli\u003eQ: How does the integrated 24 VDC loop power supply simplify field transmitter wiring?\u003c\/li\u003e\n\u003cli\u003eA: The internal loop power supply provides up to 100 mA to energize external two-wire 4-20 mA transmitters directly, eliminating the need for separate external field power distribution blocks.\u003c\/li\u003e\n\u003cli\u003eQ: What shielding practices apply when wiring 4-20 mA analog channels to prevent noise?\u003c\/li\u003e\n\u003cli\u003eA: Analog input and output lines require individually shielded twisted-pair conductors, with drain wires grounded strictly at a single chassis point to eliminate ground potential loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the module securely onto a standard 35 mm DIN rail inside an enclosure rated appropriately for the target ambient environment.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate vertical clearance above and below the module to allow unhindered air circulation across thermal dissipation vents.\u003c\/li\u003e\n\u003cli\u003eConnect the central earth grounding terminal directly to the panel DIN rail or cabinet ground busbar using a short, low-impedance bonding wire.\u003c\/li\u003e\n\u003cli\u003eVerify input power supply voltage remains strictly within 24 VDC limits prior to connecting M12 field signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50738659197180,"sku":"8200-1203","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8200-1203.jpg?v=1785376954","url":"https:\/\/www.electronicplc.com\/products\/woodward-8200-1203-linknet-ht-analog-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}