{"product_id":"woodward-8440-1923-easygen-3200-5-genset-controller","title":"Woodward 8440-1923 easYgen-3200-5 Genset Controller","description":"\u003cp\u003eConfigured for complex generator management, multi-unit load sharing, and breaker synchronization in distributed power generation networks, the \u003cstrong\u003eWoodward 8440-1923\u003c\/strong\u003e (\u003cstrong\u003e8440-1923\u003c\/strong\u003e easYgen-3200-5 Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-1923\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.5 cm x 21.5 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range (-20 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Operating Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eeasYgen-3000 Series (easYgen-3200-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eComplex Generator Management \u0026amp; Synchronizing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermal Heat Sink Dissipation \u0026amp; Actuator Loop Feedback\u003c\/h3\u003e\n\u003cp\u003eInternal voltage transformation and display backlighting generate operational heat conducted across the rugged rear metal housing. Effective thermal heat sink dissipation prevents internal thermal stress and drift across panel mounting installations. High-speed microprocessors compute voltage vectors, phase angles, and frequency differentials to drive dynamic speed and voltage bias outputs, maintaining rapid actuator loop feedback response for smooth automatic generator synchronization and proportional load sharing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How should CANbus communication lines between easYgen controllers be terminated?\u003c\/li\u003e\n\u003cli\u003eA: Inter-controller CAN networks require twisted-shielded cable with 120 ohm terminating resistors installed at both physical ends of the communication bus.\u003c\/li\u003e\n\u003cli\u003eQ: What grounding procedures apply to analog input and pickup sensing channels?\u003c\/li\u003e\n\u003cli\u003eA: All magnetic pickup inputs and 4-20 mA sensor conductors must use twisted-shielded pair cable with the shield drain wire connected to a single chassis ground point.\u003c\/li\u003e\n\u003cli\u003eQ: What panel mounting precautions ensure proper environmental sealing?\u003c\/li\u003e\n\u003cli\u003eA: Secure the controller into the panel cutout using all supplied mounting clamps, ensuring the perimeter gasket is evenly compressed against a flat metal enclosure face.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the unit into the standard panel cutout and tighten all rear screw-clamp fasteners evenly to ensure dust-tight sealing.\u003c\/li\u003e\n\u003cli\u003eRoute AC current transformer lines, potential transformer sensing wires, and low-voltage DC communication cables in separate grounded conduits.\u003c\/li\u003e\n\u003cli\u003eConnect a heavy-gauge earth jumper from the rear chassis grounding stud directly to the main switchgear ground bar.\u003c\/li\u003e\n\u003cli\u003eVerify potential transformer ratios, CT polarity, and 24 VDC auxiliary supply wiring prior to energizing control power circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50738831393020,"sku":"8440-1923 EASYGEN-3200-5","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-1923_EASYGEN-3200-51.jpg?v=1785376956","url":"https:\/\/www.electronicplc.com\/products\/woodward-8440-1923-easygen-3200-5-genset-controller","provider":"Electronic PLC","version":"1.0","type":"link"}