{"product_id":"yokogawa-aav144-s00-a4s10-analog-input-module","title":"Yokogawa AAV144-S00\/A4S10 Analog Input Module","description":"\u003cp\u003eConfigured for precision signal acquisition in process control networks, the \u003cstrong\u003eYokogawa AAV144-S00\/A4S10\u003c\/strong\u003e (\u003cstrong\u003eAAV144-S00\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution of user-configurable analog voltage processing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAAV144-S00\u003c\/strong\u003e: Base designation for a configurable analog voltage input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA4S10\u003c\/strong\u003e: Suffix indicating specific hardware configuration for signal range and protocol support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAV144-S00\/A4S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJAPAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e144 mm x 90 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified (24 VDC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage (user-configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AAV144-S00\/A4S10 module interfaces with field instrumentation to provide scalable voltage-to-current signal conversion within DCS architectures. The module implements a standard HART protocol stack to facilitate data exchange with process sensors. Internal hardware is engineered to support channel-to-channel isolation, reducing the impact of common-mode interference on low-level analog signals. The input circuitry includes configurable voltage scaling to accommodate diverse field sensor requirements, ensuring signal integrity across the designated 0-10 V input range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AAV144-S00\/A4S10 be reconfigured for different voltage inputs while the module is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Configuration adjustments must be performed through the system software interface while the module is in an offline or maintenance state to prevent transient signal output on the current loop.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of hot-swapping under normal operational conditions?\u003c\/p\u003e\n\u003cp\u003eA: No. The AAV144-S00\/A4S10 does not support hot-swapping. The module must be isolated from the 24 VDC supply and the backplane communication bus before physical removal or installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module within a standard rack enclosure, ensuring proper alignment with backplane connectors to prevent pin damage during insertion.\u003c\/li\u003e\n\u003cli\u003eVerify that the ambient operating environment remains within the -40 deg C to 80 deg C range, providing adequate ventilation for the specified 60 mm depth clearance.\u003c\/li\u003e\n\u003cli\u003eTerminate shielded signal cables at the module terminals, ensuring the shield is grounded at the cabinet entry point to minimize electromagnetic noise susceptibility.\u003c\/li\u003e\n\u003cli\u003eConfirm that the input scaling is correctly set in the controller configuration before energizing the field device loops.\u003c\/li\u003e\n\u003cli\u003eCheck that all mounting screws are tightened to secure the module against vibration and to maintain a reliable earth connection to the chassis.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49253192401148,"sku":"AAV144-S00\/A4S10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAV144-S00A4S10.jpg?v=1783302013","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-aav144-s00-a4s10-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}