{"product_id":"yokogawa-akb331-m005-signal-cable","title":"Yokogawa AKB331-M005 Signal Cable","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AKB331-M005\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAKB331-M005\u003c\/strong\u003e Signal Cable, operates as a dedicated hardware component for high-density analog and digital signal interconnection between I\/O modules and terminal boards within CENTUM VP and ProSafe-RS control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eM005\u003c\/td\u003e\n\u003ctd\u003eCable length of 5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAKB331-M005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard cable weight per 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 meters length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive interconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e50-pin to 50-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSDV144, SDV531, SDV53A, SDV541, SAT145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Interconnection and Shielding\u003c\/h3\u003e\n\u003cp\u003eThe AKB331-M005 is a high-density, multi-core cable assembly engineered to provide stable signal propagation for analog and digital I\/O modules. The 50-pin connector interface is designed for secure mating with Yokogawa's terminal board series, ensuring minimal contact resistance and consistent signal integrity. The cable construction includes individual core insulation and overall shielding to minimize crosstalk and electromagnetic interference (EMI) between adjacent signal paths. This specific 5-meter variant is utilized for structured cabinet wiring where signal modules and termination blocks are separated by defined cable tray routes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AKB331-M005 cable be used to connect different I\/O module types?\u003c\/p\u003e\n\u003cp\u003eA: The cable is designed for specific compatibility with the SDV144, SDV531, SDV53A, SDV541, and SAT145 series modules. Always verify the pinout compatibility in the hardware manual before utilizing it with other hardware types.\u003c\/p\u003e\n\u003cp\u003eQ: Is this cable suitable for high-vibration industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the connectors are fully seated and the cable is secured using strain relief accessories at both the module and terminal board ends to prevent mechanical fatigue on the pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect both 50-pin connector housings for bent or pushed-in pins prior to installation.\u003c\/li\u003e\n\u003cli\u003eAlign the connectors squarely with the module\/terminal board ports and ensure the locking mechanisms are fully latched.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through dedicated signal cable trays; do not bundle with high-voltage power conduits or AC motor supply lines.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius of at least 10 times the cable outer diameter to prevent internal conductor breakage.\u003c\/li\u003e\n\u003cli\u003eUse tie-wraps to secure the cable at regular intervals to prevent the weight of the 5-meter assembly from placing excessive strain on the connector headers.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49208346738940,"sku":"AKB331-M005","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AKB331-M005.jpg?v=1781761291","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-akb331-m005-signal-cable","provider":"Electronic PLC","version":"1.0","type":"link"}