{"product_id":"yokogawa-alr121alr121-s00-communication-module","title":"Yokogawa ALR121(ALR121-S00) Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ALR121-S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eALR121\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for serial communication interfacing within distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eALR121\u003c\/strong\u003e: Base model designation for the Serial Communication Module (RS-232-C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS00\u003c\/strong\u003e: Standard configuration code denoting the base specification without specialized hazardous area options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eALR121-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC (System backplane powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eRS-232-C Serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Communication Interface\u003c\/h3\u003e\n\u003cp\u003eThe ALR121-S00 is designed to facilitate bidirectional data exchange between field devices and the Field Control Unit (FCU) via RS-232-C serial protocol. The module supports deterministic communication profiles required for high-speed integration of subsystems, such as intelligent instrumentation, analyzers, or third-party programmable controllers. By regulating backplane bus communication velocity, the module ensures that serial data frames are synchronized with the DCS scan cycle, preventing jitter and packet loss. The design incorporates galvanic isolation for the serial ports to prevent common-mode noise propagation between the connected subsystem and the DCS chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ALR121-S00 support hot-swapping during active DCS operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The ALR121-S00 must be removed or inserted only after de-energizing the specific bus segment or following the system-specific maintenance procedure to avoid communication disruptions on the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be configured for other serial standards like RS-485?\u003c\/p\u003e\n\u003cp\u003eA: No. The ALR121-S00 is natively designed for RS-232-C serial communication. For RS-485 requirements, refer to the corresponding Yokogawa module specifications (such as the ALR111 or ALR121-S5x variants).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated communication slot on the I\/O rack, ensuring the module connector is flush against the backplane.\u003c\/li\u003e\n\u003cli\u003eUtilize high-quality, double-shielded RS-232 cables for all serial links; ensure the cable length does not exceed 15 m to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eGround the cable shield only at one end (typically the DCS cabinet side) to prevent ground loops, which can introduce noise into the serial data stream.\u003c\/li\u003e\n\u003cli\u003ePerform a loopback test using the module's diagnostic software features prior to establishing final connectivity with the remote subsystem to verify proper transceiver operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49983875383548,"sku":"ALR121(ALR121-S00)","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ALR121_ALR121-S00_1.jpg?v=1784079918","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-alr121alr121-s00-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}