{"product_id":"yokogawa-ejx110a-ehs5g-917db-ff1-d1-x2-hc-a-pressure-transmitter","title":"Yokogawa EJX110A-EHS5G-917DB\/FF1\/D1\/X2\/HC\/A Pressure Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa EJX110A-EHS5G-917DB\/FF1\/D1\/X2\/HC\/A\u003c\/strong\u003e is a premium-performance differential pressure transmitter from the \u003cstrong\u003eDPharp EJX series\u003c\/strong\u003e. It is engineered for critical process control applications requiring high accuracy, stability, and intelligence, often utilized in differential pressure, liquid level, and flow measurement.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Code Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEJX110A\u003c\/strong\u003e: Base model for Differential Pressure Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Output signal (4 to 20 mA DC with HART 7).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH\u003c\/strong\u003e: Measurement span (High\/Medium range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Wetted parts material (Stainless Steel 316L).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5\u003c\/strong\u003e: Process connection (specific flange type\/size).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG\u003c\/strong\u003e: Fill fluid (specific high-temperature\/process-compatible fluid).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e917DB\/FF1\/D1\/X2\/HC\/A\u003c\/strong\u003e: Configuration package denoting explosion protection (FM\/ATEX\/IECEx), local indicator, Hastelloy C wetted parts, and mounting hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEJX110A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e$\\pm 0.025\\%$ of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e$\\pm 0.1\\%$ of URL for 15 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e90 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 °C (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e10.5 to 42 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eHART 7, FOUNDATION Fieldbus, Wireless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSensing Technology\u003c\/h3\u003e\n\u003cp\u003eThe EJX110A utilizes the advanced \u003cstrong\u003eDPharp\u003c\/strong\u003e digital silicon resonant sensor. By measuring pressure directly as a digital frequency, the device achieves high repeatability and sensitivity while remaining inherently resistant to temperature-induced drift and static pressure effects.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Why choose the EJX110A over standard transmitters?\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eA: The EJX series is Yokogawa’s top-tier transmitter line, offering superior accuracy ($\\pm 0.025\\%$) and a remarkable 15-year stability guarantee, making it ideal for safety-critical and high-accuracy billing or process optimization tasks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the significance of the \"HC\" (Hastelloy C) designation?\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eA: The \"HC\" option signifies that the wetted parts are constructed from Hastelloy C-276, providing excellent resistance to aggressive, corrosive media compared to standard 316L stainless steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the transmitter vertically. Ensure process connections are free of debris and that proper gaskets are utilized according to the process pressure rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the local indicator or a HART handheld communicator to set the Zero and Span. Perform a multi-point calibration if the application requires extreme precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always connect the transmitter housing to the plant’s instrument earth ground. This is vital for the proper function of the sensor's internal EMI\/RFI noise rejection circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Integrity:\u003c\/strong\u003e Ensure the loop resistance matches the power supply capability (10.5–42 V DC) to prevent voltage drop issues during high-speed HART communication.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49987372908796,"sku":"EJX110A-EHS5G-917DB\/FF1\/D1\/X2\/HC\/A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/EJX110A-EHS5G-917DBFF1D1X2HCA1.jpg?v=1784079918","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-ejx110a-ehs5g-917db-ff1-d1-x2-hc-a-pressure-transmitter","provider":"Electronic PLC","version":"1.0","type":"link"}