{"product_id":"yokogawa-nc1y16r-08-digital-output-module","title":"Yokogawa NC1Y16R-08 Digital Output Module","description":"\u003cp\u003eConfigured for high-density signal distribution within PLC architectures, the \u003cstrong\u003eYokogawa NC1Y16R-08\u003c\/strong\u003e (\u003cstrong\u003eNC1Y16R-08\u003c\/strong\u003e Digital Output Module) provides direct physical and electrical execution of 16-channel relay-based control state switching.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNC1Y16R-08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 13.5 cm x 10.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Capacity\u003c\/td\u003e\n\u003ctd\u003e2 A per point, 8 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Performance\u003c\/h3\u003e\n\u003cp\u003eThe NC1Y16R-08 architecture is optimized for robust digital control within Yokogawa FA-M3 and STARDOM platforms, facilitating efficient I\/O density scaling for relay-based field applications. The module manages deterministic output state propagation, ensuring that backplane bus communication velocity remains synchronized with the master controller. The hardware design features two groups of 8 points, each sharing a common return path, which simplifies wiring in modular cabinet assemblies. By maintaining isolation between the relay coils and the backplane logic, the module prevents potential electrical feedback or transients from impacting the deterministic performance of the control processor.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the output relays replaceable in the field if a point fails?\u003c\/p\u003e\n\u003cp\u003eA: No. The relays are integrated into the module circuitry. If a point failure occurs due to relay contact welding or coil fatigue, the entire module must be replaced to maintain the integrity of the safety control loop.\u003c\/p\u003e\n\u003cp\u003eQ: How should the common terminals be configured for mixed-voltage applications?\u003c\/p\u003e\n\u003cp\u003eA: The module supports 8 points per common group. If different voltages or phases are used, ensure they are segregated into separate common groups; never bridge different voltage sources across the same common terminal to prevent hazardous short-circuit conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the field-side supply is de-energized before terminating wires to the terminal block to prevent electrical shock or inadvertent activation of connected loads.\u003c\/li\u003e\n\u003cli\u003eEnsure that the total current draw per common group does not exceed 8 A to prevent thermal degradation of the internal traces.\u003c\/li\u003e\n\u003cli\u003eUtilize external surge suppression (e.g., flyback diodes for DC loads or varistors for AC loads) when driving inductive devices to protect the relay contacts from pitting and material transfer.\u003c\/li\u003e\n\u003cli\u003eRoute output signal wiring away from high-speed data cables to prevent EMI coupling that could induce intermittent signal noise on adjacent input modules.\u003c\/li\u003e\n\u003cli\u003eSecure the module to the backplane rack and verify all field connections are torqued according to terminal block specifications to ensure long-term mechanical stability.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49245961879804,"sku":"NC1Y16R-08","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NC1Y16R-082.jpg?v=1783043696","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-nc1y16r-08-digital-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}