{"product_id":"yokogawa-nfar181-s50-r8s10-rtd-tc-input-module","title":"Yokogawa NFAR181-S50\/R8S10 RTD\/TC Input Module","description":"\u003cp\u003eConfigured for high-density temperature signal acquisition in industrial process networks, the \u003cstrong\u003eYokogawa NFAR181-S50\/R8S10\u003c\/strong\u003e (\u003cstrong\u003eNFAR181-S50\/R8S10\u003c\/strong\u003e RTD\/TC Input Module) provides direct physical signal conditioning and digitalization of multi-type thermal sensor inputs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNFAR181: Base analog input module identifier.\u003c\/li\u003e\n\u003cli\u003eS50: Standard performance hardware iteration.\u003c\/li\u003e\n\u003cli\u003eR8S00: Base pressure clamp terminal block configuration.\u003c\/li\u003e\n\u003cli\u003eR8S10: Terminal block configuration incorporating surge absorber circuitry for enhanced transient protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAR181-S50\/R8S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e12 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eTC (J, K, E, B, R, S, T, N), mV, RTD (Pt100, JPt100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 minute between input and system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe NFAR181-S50\/R8S10 incorporates robust galvanic isolation to prevent ground loop currents from affecting low-level thermocouple and RTD signal integrity. The module utilizes active cold junction compensation (CJC) for thermocouple inputs and excitation current steering for three-wire RTD measurements, ensuring precision across the entire extended temperature range. The implementation of surge absorber circuitry (R8S10 variant) provides additional protection against common-mode transient voltage spikes common in field wiring environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support mixed signal types across the 12 available channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed to handle multiple input types, including varied thermocouple calibrations and RTD sensors, simultaneously across its 12 channels. Ensure the system software configuration is accurately mapped to the specific sensor type connected to each terminal pair to maintain measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: How does the surge absorber in the R8S10 variant affect signal bandwidth?\u003c\/p\u003e\n\u003cp\u003eA: The surge absorber is designed to shunt transient voltage surges without impacting the low-frequency DC signal path required for temperature measurement. It does not introduce significant attenuation or signal latency within the specified 1 second data refresh cycle.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is properly grounded, as the module relies on a stable reference potential for high-accuracy RTD\/TC measurement.\u003c\/li\u003e\n\u003cli\u003eWhen connecting three-wire RTDs, ensure that the lead wire resistance is balanced to minimize measurement errors caused by unequal lead voltage drops.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate compensation cabling for thermocouple inputs to ensure the reference junction temperature is maintained at the terminal block interface.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal block is seated securely to the module front panel to ensure reliable contact for both the signal path and the integrated surge protection.\u003c\/li\u003e\n\u003cli\u003eIn explosion-proof (Ex) rated environments, adhere strictly to the installation documentation regarding hazardous area wiring practices and barrier requirements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49219704946940,"sku":"NFAR181-S50\/R8S10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFAR181-S50.jpg?v=1780971137","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-nfar181-s50-r8s10-rtd-tc-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}