{"product_id":"yokogawa-sr-508-00-safety-relay-module","title":"YOKOGAWA SR-508-00 Safety Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SR-508-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSR-508\u003c\/strong\u003e Safety Relay Module, operates as a dedicated hardware component for critical process interlock and signal isolation within safety-instrumented system (SIS) network architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR-508-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg (0.11 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (35-40 mA input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFail-Safe State Execution and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe SR-508-00 is engineered to maintain high-integrity signal paths required for safety-instrumented systems. The internal relay mechanism facilitates galvanic isolation between the 24 VDC control logic and field-side instrumentation, which is required to protect sensitive safety controllers from electrical transients. The module is designed for fail-safe state execution; upon loss of input power or detection of an internal control circuit fault, the relay de-energizes to transition the process loop to a pre-defined safe operational state, minimizing the risk of uncontrolled process excursions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SR-508-00 be used in applications requiring SIL-rated performance?\u003c\/p\u003e\n\u003cp\u003eA: The SR-508-00 is designed for safety-related signaling. Verify that the module's safety parameters and failure rates align with the specific Safety Integrity Level (SIL) requirements of the installation's safety logic loop.\u003c\/p\u003e\n\u003cp\u003eQ: Does the LED status indicator provide information on contact state or input power?\u003c\/p\u003e\n\u003cp\u003eA: The integrated LED status indicator provides visual confirmation of the input coil excitation. When the LED is illuminated, the internal relay coil is energized and the output contacts have transitioned to their active state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMounting: Snap the module onto a standard 35 mm DIN-rail. Ensure the locking clip is fully engaged to prevent mechanical vibration from compromising the terminal connections.\u003c\/li\u003e\n\u003cli\u003eWiring: Use appropriately rated wire gauge for the terminal blocks. Ensure all connections are secured with proper torque to prevent contact resistance, which is detrimental to safety signal integrity.\u003c\/li\u003e\n\u003cli\u003eElectrical Protection: Install the module in an IP20-rated or higher enclosure to prevent dust ingress and accidental contact with live electrical components.\u003c\/li\u003e\n\u003cli\u003eMaintenance: During routine inspection, verify that the LED status indicator accurately tracks the control system's logic state. If the relay fails to transition despite an active input, replace the module immediately to maintain the safety function.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49235864453372,"sku":"SR-508-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SR-508-001.jpg?v=1782781500","url":"https:\/\/www.electronicplc.com\/products\/yokogawa-sr-508-00-safety-relay-module","provider":"Electronic PLC","version":"1.0","type":"link"}