Configured for precision pressure monitoring in industrial automation systems, the Yokogawa FP101-M31-CN0A*B (FP101-M31-CN0A*B Pressure Sensor) provides direct physical signal execution via an analog loop.
Configured for precision pressure monitoring in industrial automation systems, the Yokogawa FP101-M31-CN0A*B (FP101-M31-CN0A*B Pressure Sensor) provides direct physical signal execution via an analog loop.
Suffix Breakdown & Model Matrix
Model
Component Description
FP101
Base Pressure Sensor series (Silicon Micromachining)
-M31-CN0A*B
Specific configuration for process connection and electrical output
Hardware Specifications
Parameter
Specification
Model
FP101-M31-CN0A*B
Brand
Yokogawa
Origin
Japan
Weight
1.5kg
Dimensions
Standard industrial sensor profile
Operating Temp
-40 deg C to +85 deg C
Power Consumption
Loop powered
Pressure Range
0-10 kPa
Output
4-20 mA
Accuracy
+/- 0.25% of full scale
Process Control Connectivity and Integration
The FP101-M31-CN0A*B utilizes silicon micromachining technology to provide stable pressure data within process control architectures. The sensor electronics are engineered to support the 4-20 mA HART loop protocol integration, ensuring that accurate process variables are transmitted with digital diagnostic capability. The internal transducer design features channel-to-channel isolation from the process environment, protecting the gauge from thermal drift and pressure spikes. Furthermore, the unit incorporates cold junction compensation mechanisms where necessary to maintain precision across the entire operating temperature range, ensuring high stability in demanding field instrumentation environments.
Frequently Asked Questions
Q: Can the FP101-M31-CN0A*B be used in explosive atmospheres?
A: Verification of the specific unit's certification label is required. Standard models are typically designed for general industrial use; ensure compliance with local hazardous area zoning requirements before installation.
Q: How is the zero-point calibration maintained in this pressure sensor?
A: The sensor employs an internal resonant silicon design that minimizes long-term drift. Periodic calibration checks should be performed using a certified pressure calibrator to verify the output against the 4-20 mA baseline.
Field Installation Guidelines
Ensure the process connection is free of debris or contaminants before mounting the sensor to prevent clogging of the pressure port.
Utilize appropriate thread sealant or gaskets compatible with the process fluid to ensure a leak-proof connection at the rated pressure range.
Terminate the 4-20 mA output signal using shielded twisted-pair cabling; connect the shield to a single, common earth point to minimize electromagnetic interference.
Verify that the ambient temperature at the installation site does not exceed the -40 deg C to +85 deg C operating limit.
Secure the unit using the designated process mounting points to prevent mechanical vibration from affecting the integrity of the pressure measurement.