Description

The 8111 High Density Main Chassis serves as the fundamental structural backbone for the Invensys Triconex Triple Modular Redundant (TMR) safety system. This chassis functions as the primary power supply...

29 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 5

SKU: 8111
Proveedora: Triconex
tipo: Main Chassis

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The 8111 High Density Main Chassis serves as the fundamental structural backbone for the Invensys Triconex Triple Modular Redundant (TMR) safety system. This chassis functions as the primary power supply rack and hosting environment for critical control processors and I/O modules. Designed for high-stakes industrial sectors such as oil and gas refining, power generation, and chemical processing, the 8111 provides the physical and electrical integrity required to maintain SIL 3 safety integrity levels. By offering a centralized, vibration-resistant mounting solution with integrated power distribution, this chassis minimizes complex wiring and reduces potential points of failure, directly mitigating the risk of unplanned system downtime in mission-critical applications.

Features

  • Passive backplane architecture for zero-latency communication between triplicated controller sets.
  • Dedicated slots for dual-redundant power supply modules to ensure continuous operation.
  • High-density module packing design to optimize cabinet footprint while maintaining thermal dissipation.
  • Precision-machined card guides and connector alignments for reliable hot-swappable module insertion.
  • Robust metallic construction providing EMI shielding for sensitive internal electronics.

Applications

The 8111 chassis is utilized in mission-critical safety and control applications, including emergency shutdown systems (ESD), burner management systems (BMS), and turbomachinery control. It is designed for use in environments requiring high availability and fault tolerance, such as petrochemical plants, refineries, and power generation facilities.

Technical Specifications

Model 8111
Brand Invensys Triconex
Category High Density Main Chassis / Power Supply Rack
Operating Temperature 0 to 60 deg C
Storage Temperature -40 to 85 deg C
Relative Humidity 5-95 percent non-condensing
Mounting Standard 19-inch Rack Mount or Panel Mount

Installation Guidelines

  • Ensure the chassis is mounted in a clean, dry environment with adequate ventilation to prevent overheating.
  • Verify that the rack or panel provides a secure, vibration-free mounting surface.
  • Always power down the system before installing or removing power supply modules or I/O cards to prevent electrical arcing or damage.
  • Ensure proper grounding of the chassis to the cabinet ground bus to maintain EMI shielding effectiveness.
  • Route signal and power cables separately to minimize noise interference.
  • Handle modules using ESD-safe practices to prevent damage to internal circuitry.

FAQ

What is the primary function of the 8111 chassis?

The 8111 acts as the main rack for the Triconex TMR system, housing the main processors, I/O modules, and redundant power supplies while providing the backplane communication path.

Is this chassis compatible with all Triconex systems?

The 8111 is specifically designed for the Triconex TMR series. Please verify your specific system revision and module compatibility requirements before installation.