Ir directamente a la información del producto
1 de 3

Allen-Bradley 1756-IF16 ControlLogix 16-Channel Analog Input Module

Allen-Bradley 1756-IF16 ControlLogix 16-Channel Analog Input Module

The Allen-Bradley 1756-IF16 is a high-performance 16-channel analog input module designed for the ControlLogix platform. It provides precise acquisition of voltage and current signals, facilitating robust monitoring and process control...

29 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 7

SKU: 1756-IF16
Proveedora: Allen-Bradley

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The Allen-Bradley 1756-IF16 is a high-performance 16-channel analog input module designed for the ControlLogix platform. It provides precise acquisition of voltage and current signals, facilitating robust monitoring and process control across diverse industrial environments. The module supports flexible input configurations including 16 single-ended channels, 8 differential channels, or 4 high-speed differential channels.

Features

  • 16-bit resolution for high-accuracy measurement of analog process variables.
  • Software-configurable input ranges including ±10.25 V DC, 0–20.5 mA, and 4–20.5 mA.
  • Selectable data formats: IEEE 32-bit floating-point and 16-bit integer (2's complement).
  • Integrated diagnostic features including open-circuit detection and channel-level status monitoring.
  • Sigma-Delta A/D conversion for superior noise immunity and signal stability.
  • Support for real-time channel sampling and configurable engineering unit scaling.

Applications

This module is engineered for demanding automation tasks in sectors such as oil and gas, chemical processing, power generation, and water treatment. It is commonly utilized for:

  • Monitoring pressure, temperature, flow, and level sensors.
  • Interface with vibration monitoring systems and valve positioners.
  • Integration into PID control loops for precise process management.
  • Data acquisition for high-speed diagnostic systems.

Technical Specifications

Model 1756-IF16
Input Channels 16 Single-ended / 8 Differential
Resolution 16-bit
Input Ranges ±10.25V, 0-10.25V, 0-5.125V, ±20.5mA, 0-20.5mA, 4-20.5mA
Backplane Power 2.33 W (150mA @ 5.1V DC; 65mA @ 24V DC)
Isolation 250V continuous (channel to backplane)
Operating Temp 0 degC to 60 degC
Relative Humidity 5 to 95% non-condensing

Installation Guidelines

  • Ensure the ControlLogix chassis is powered down before inserting or removing the module to prevent electrical damage.
  • Use 1756-TBCH or 1756-TBS6H removable terminal blocks for secure field wiring.
  • Always utilize shielded, twisted-pair cabling (22–14 AWG) to minimize EMI; terminate drain wires to a dedicated chassis ground.
  • Verify the wiring mode (single-ended vs. differential) in the module configuration within the controller software before applying power.
  • The module does not provide internal loop power; ensure external power supplies are correctly integrated for 2-wire transmitter loops.

FAQ

What is the primary function of the 1756-IF16?

The 1756-IF16 is an analog input module that converts field-level voltage or current signals into digital data for processing by a ControlLogix controller.

Can I change the wiring mode after configuration?

No, the wiring mode (single-ended or differential) is defined in the module's communication format within the I/O tree. Changing this requires deleting and re-adding the module in the project file.

Does this module provide excitation power to sensors?

No, this module does not provide loop power. External power sources are required for transmitters that need excitation.

How are 4-20mA signals measured?

The module measures voltage. For 4-20mA signals, the current is routed through an internal 250-ohm resistor (via correct terminal wiring) to create a measurable voltage drop.