Ir directamente a la información del producto
1 de 3

Digital Input Terminal Block Yokogawa ATB5D-00

Digital Input Terminal Block Yokogawa ATB5D-00

The Yokogawa ATB5D-00, also cataloged as the ATB5D-00 Digital Input Terminal Block, operates as a dedicated hardware component for field wiring interface and signal distribution within CENTUM VP control system...

25 la gente está viendo esto ahora mismo

DisponibilidadEn existencias

SKU: ATB5D-00
Proveedora: Yokogawa

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The Yokogawa ATB5D-00, also cataloged as the ATB5D-00 Digital Input Terminal Block, operates as a dedicated hardware component for field wiring interface and signal distribution within CENTUM VP control system platforms.

Hardware Specifications

Parameter Specification
Model ATB5D-00
Brand Yokogawa
Origin Japan
Weight 0.4 kg
Dimensions Compact form factor
Operating Temp -20 to 70 deg C (standard industrial range)
Power Consumption Not applicable (Passive component)
System Compatibility CENTUM VP, ADV151 modules
Mounting Type Rack or chassis mount

Process Control and Signal Interface

The ATB5D-00 functions as a passive interface unit designed to facilitate the connection between field instrumentation and the ADV151 digital input modules. It supports dual-redundant input configurations, allowing for high availability in critical loop monitoring. The internal circuit design ensures channel-to-channel isolation consistency when interfaced with the I/O base. Signal integrity is maintained via high-density terminal blocks that minimize contact resistance, which is critical for discrete input state detection in distributed control system applications.

Frequently Asked Questions

Q: Does the ATB5D-00 require an external power supply for operation?

A: No. The ATB5D-00 is a passive terminal block unit. Power for the field sensors is typically routed through the module from the connected I/O card or an external field power supply, depending on the specific loop design.

Q: Can this terminal block be used for redundant I/O configurations?

A: Yes. The unit is specifically engineered to support dual-redundant input configurations for ADV151 modules, allowing for continuous signal path availability during maintenance or module-level failures.

Field Installation Guidelines

  • Mount the unit on a standard chassis or rack within the I/O cabinet, ensuring sufficient space for field cable trunking.
  • Torque all terminal screws to the manufacturer's recommended values to prevent high-resistance connections or intermittent signal loss.
  • Identify and label all field wires according to the project loop diagrams before insertion into the block to ensure correct polarity and channel mapping.
  • When utilizing redundant configurations, ensure that the wiring path maintains physical separation where required by system safety standards to prevent common-cause failures.