Emerson DeltaV KJ4010X1-BG1 12P0830X072 Right LocalBus Extender

Emerson DeltaV KJ4010X1-BG1 12P0830X072 Right LocalBus Extender

Description

The Emerson DeltaV KJ4010X1-BG1 (12P0830X072) is a Right LocalBus Extender designed for the DeltaV scalable process control system. This module is essential for expanding the LocalBus backplane, enabling the interconnection...

19 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 5

SKU: KJ4010X1-BG1 12P0830X072
Proveedora: Emerson

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The Emerson DeltaV KJ4010X1-BG1 (12P0830X072) is a Right LocalBus Extender designed for the DeltaV scalable process control system. This module is essential for expanding the LocalBus backplane, enabling the interconnection of multiple I/O carriers across different rows or enclosures within a control cabinet. It ensures high-speed data synchronization and maintains power distribution integrity across the extended bus, providing the necessary flexibility for large-scale distributed control system (DCS) deployments.

Features

  • Facilitates physical expansion of the DeltaV LocalBus backplane.
  • Enables signal transition between carrier rows via dedicated cable assemblies.
  • Designed for high-availability industrial environments including oil, gas, and chemical processing.
  • Rated for operation in hazardous locations (Zone 2).
  • Conformal coating compliant with ISA-S71.04-1985 Class G3 for protection against corrosive contaminants.

Applications

This module is used in industrial automation environments where the I/O count requires multiple carrier rows. It is commonly deployed in oil refineries, chemical processing plants, and mining operations where robust, reliable communication between the controller and remote I/O is required.

Technical Specifications

Model KJ4010X1-BG1
Part Number 12P0830X072
Module Type Right LocalBus Extender
LocalBus Power Rating 12.6 VDC at 8 A
Max System Length 6.5 meters (combined carriers and extenders)
Operating Temperature -40 to 70 deg C
Relative Humidity 5 to 95 percent (non-condensing)
Protection Rating IP 20
Shock Resistance 10g 1/2 Sinewave for 11 msec
Vibration Resistance 1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)

Installation Guidelines

  • Ensure all power is de-energized before connecting or disconnecting LocalBus cables.
  • The module must be installed as the physical termination point on the right side of a carrier row.
  • Verify that the total combined length of I/O carriers and LocalBus extenders does not exceed 6.5 meters to maintain signal timing integrity.
  • Handle with standard ESD precautions to prevent damage to internal circuitry.
  • Ensure the environment meets the specified temperature and humidity ranges for optimal performance.

Compliance and Certifications

The KJ4010X1-BG1 is certified for use in hazardous atmospheres, specifically II 3 G, Nemko 02ATEX431U, and EEx nA IIC T4, making it suitable for Zone 2 installations.

FAQ

What is the primary function of the KJ4010X1-BG1?

It acts as a right-side interface to extend the DeltaV LocalBus, allowing you to connect I/O carriers across multiple rows or cabinets while maintaining signal and power integrity.

Can this module be used in corrosive environments?

Yes, the module is designed to meet ISA-S71.04-1985 Class G3 standards, providing resistance to corrosive airborne contaminants.

Is it safe to hot-swap this module?

No. All power must be de-energized before connecting or disconnecting the LocalBus cables to prevent electrical damage or signal disruption.