Description

The Emerson KJ4001X1-BA2 (also identified as 12P1562X012 or VE3051CO) is a 2-wide power controller carrier designed specifically for the DeltaV M-Series automation system. This carrier serves as the essential mounting...

29 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 7

SKU: KJ4001X1-BA2 VE3051CO 12P1562X012
Proveedora: Emerson

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The Emerson KJ4001X1-BA2 (also identified as 12P1562X012 or VE3051CO) is a 2-wide power controller carrier designed specifically for the DeltaV M-Series automation system. This carrier serves as the essential mounting and electrical interface for power supplies and controllers, providing stable power distribution across the system LocalBus. It is engineered to support mission-critical industrial processes, ensuring reliable operation in environments such as petrochemical refining, power generation, and large-scale manufacturing.

Features

  • Designed for seamless integration with DeltaV M-Series hardware.
  • Provides a secure, high-capacity interface for power distribution.
  • Supports a maximum input of 30 VDC at 8 A.
  • Robust construction suitable for demanding industrial environments.
  • Compatible with standard DeltaV LocalBus configurations.

Applications

This carrier is intended for use in DeltaV control systems where stable power and controller mounting are required. It is commonly deployed in distributed control system (DCS) architectures for process automation, safety-critical monitoring, and industrial facility management.

Technical Specifications

Model KJ4001X1-BA2 (12P1562X012)
Brand Emerson
Series DeltaV M-Series
Product Type Power Controller 2-Wide Carrier
Input Power 30 VDC at 8 A (Max)
Operating Temperature 0 to 60 deg C
Relative Humidity 5 to 95 percent (Non-Condensing)
Hazardous Area Rating II 3 G / EEx nA IIC T4
ATEX Certification Nemko No. 02ATEX431U
Airborne Contaminants ISA-S71.04-1985 Class G3
Protection Rating IP 20
Shock Resistance 10g 1/2 Sinewave for 11 msec
Vibration Resistance 1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)
Max Bus Length 6.5 meters (Total)

Installation Guidelines

  • Ensure the system is completely de-energized before attempting to install or remove the carrier or any associated LocalBus cables.
  • The carrier must be mounted in accordance with DeltaV M-Series hardware specifications to ensure proper cooling and electrical grounding.
  • Total length of I/O carriers and LocalBus Extenders must not exceed 6.5 meters to maintain signal integrity and power stability.
  • Use KJ4001X1-FA1 module covers on all unused slots to prevent environmental degradation and ingress of contaminants.
  • Handle with care to avoid electrostatic discharge (ESD) damage to sensitive electronic components.

FAQ

What is the primary function of the KJ4001X1-BA2?

The KJ4001X1-BA2 acts as a mounting base and power distribution interface for DeltaV M-Series controllers and power supplies, ensuring they are correctly powered and connected to the system LocalBus.

Can this carrier be used in hazardous locations?

Yes, it is rated for hazardous atmosphere locations (II 3 G / EEx nA IIC T4) and carries the Nemko 02ATEX431U certification.

What should I do with unused slots on the carrier?

To maintain the integrity of the hardware and protect against environmental factors, all unused slots must be covered using the KJ4001X1-FA1 module cover.