Ir directamente a la información del producto
1 de 3

General Electric IC698CRE020 PACSystems RX7i CPU Module

General Electric IC698CRE020 PACSystems RX7i CPU Module

Description

The IC698CRE020 is a high-performance Central Processing Unit (CPU) module designed for the GE Fanuc/Emerson PACSystems RX7i series. Engineered for demanding industrial environments, this module supports Hot Standby Redundancy, making...

18 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 6

SKU: IC698CRE020
Proveedora: General Electric
tipo: CPU Module

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The IC698CRE020 is a high-performance Central Processing Unit (CPU) module designed for the GE Fanuc/Emerson PACSystems RX7i series. Engineered for demanding industrial environments, this module supports Hot Standby Redundancy, making it an ideal solution for critical applications where continuous, uninterrupted operation is required. It features a 700 MHz processor and 10 MB of user memory, providing robust processing power for complex automation tasks.

Features

  • Designed for PACSystems RX7i rack-mounted frameworks.
  • Supports Hot Standby CPU Redundancy for high-availability systems.
  • 700 MHz clock speed for efficient logic execution.
  • 10 MB of battery-backed RAM and 10 MB of non-volatile flash memory.
  • Integrated Ethernet interface for networked communication.
  • Error Checking and Correction (ECC) to detect and correct single-bit memory errors.
  • Physical memory protection switch to prevent unauthorized logic changes.
  • Diagnostic LEDs for real-time operational status monitoring.

Applications

This CPU module is primarily utilized in large-scale industrial automation systems requiring high reliability. It is commonly deployed in process control, material handling, and critical machine monitoring where system downtime must be minimized through redundant processing.

Technical Specifications

Model IC698CRE020
Series PACSystems RX7i
Processor Speed 700 MHz
User Memory 10 MB (Battery-backed RAM)
Non-Volatile Storage 10 MB Flash
Redundancy Hot Standby Supported
Operating Temperature 0 to 60 degC
Relative Humidity Up to 80% (non-condensing)
Mounting Chassis/Rack
Weight 0.68 kg

Installation Guidelines

  • Ensure the system power is disconnected before installing or removing the CPU module from the RX7i rack.
  • The module is designed for chassis mounting; ensure it is fully seated in the backplane slot to maintain proper electrical contact.
  • Maintain adequate ventilation around the rack to ensure the ambient temperature remains within the 0 to 60 degC operating range.
  • Follow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal components.
  • Verify that the battery is properly installed and connected to ensure the retention of calendar data and variables during power loss.
  • Route communication cables away from high-voltage power lines to minimize EMI interference.

FAQs

What is the switchover time for the IC698CRE020 in a redundant configuration?

The maximum switchover time from failure detection to the backup CPU taking control is one logic scan, with a minimum of 3.133 milliseconds.

Does this module support legacy I/O?

Yes, the IC698CRE020 is compatible with Series 90-70 discrete and analog I/O modules, as well as standard VME modules.

What is the purpose of the physical switch on the module?

The physical toggle switch allows the user to set the module to a "Memory Protect" position, which prevents accidental or unauthorized modifications to the stored control logic.