Ir directamente a la información del producto
1 de 3

GE Mark VI IS200VTURH1BAC Primary Turbine Protection Board

GE Mark VI IS200VTURH1BAC Primary Turbine Protection Board

Description

The IS200VTURH1BAC is a specialized Primary Turbine Protection module designed for the GE Speedtronic Mark VI Turbine Control System. Functioning as the core VTUR board, it provides high-integrity monitoring and...

15 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 3

SKU: IS200VTURH1BAC
Proveedora: GE FANUC

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The IS200VTURH1BAC is a specialized Primary Turbine Protection module designed for the GE Speedtronic Mark VI Turbine Control System. Functioning as the core VTUR board, it provides high-integrity monitoring and trip logic for large-scale utility turbines in power generation and heavy industrial applications. The board executes critical safety functions, including primary overspeed detection via passive pulse rate devices, shaft voltage/current monitoring, and automatic generator synchronization. By integrating emergency trip solenoid control with precision speed sensing, this module is essential for preventing catastrophic turbine failure and minimizing unscheduled downtime in high-stakes environments like thermal power plants and petrochemical facilities.

Features

  • Supports seamless integration with TRPG, TRPL, TREG, and TRPS terminal boards for signal distribution and solenoid driving.
  • Utilizes four passive pulse rate inputs to monitor turbine rotation for primary overspeed trip execution.
  • Includes hardware-level logic for automatic generator synchronizing and circuit breaker control.
  • Features dual-threshold contact voltage sensing (20 VDC HI / 6 VDC LO) for signal reliability in industrial electrical environments.
  • Dedicated hardware channels for emergency trip solenoid control.

Applications

This module is specifically engineered for use within the GE Mark VI Speedtronic control architecture. It is typically deployed in power generation facilities, thermal power plants, and large-scale petrochemical processing plants where turbine overspeed protection and precise synchronization are mission-critical requirements.

Technical Specifications

Model IS200VTURH1BAC
Series Mark VI Speedtronic
Product Type Turbine Specific Primary Trip Board
Operating Temperature 0 to 60 deg C
MPU Pulse Rate Range 2 Hz to 20 kHz
Pulse Rate Accuracy 0.05% of Reading
Trip Solenoid Outputs 3 Dedicated channels
Contact Voltage Sensing 20 VDC (HI) / 6 VDC (LO)

Installation Guidelines

  • Ensure the Mark VI control rack is powered down before inserting or removing the VTUR board to prevent electrical damage.
  • Handle the module using proper ESD (Electrostatic Discharge) protection measures to avoid damaging sensitive internal components.
  • Ensure the board is fully seated in the VME-style backplane slot and that all retaining screws are tightened to ensure proper grounding and mechanical stability.
  • Verify that all terminal board connections (TRPG, TRPL, TREG, TRPS) are correctly wired and secured before system startup.
  • Ensure adequate ventilation within the control cabinet to maintain operating temperatures between 0 and 60 deg C.

FAQ

What is the primary function of the IS200VTURH1BAC?

The IS200VTURH1BAC acts as the primary turbine protection board in the Mark VI system, responsible for monitoring turbine speed, executing overspeed trips, and managing generator synchronization.

Is this module compatible with other terminal boards?

Yes, the VTUR board is designed to interface with specific Mark VI terminal boards, including the TRPG, TRPL, TREG, and TRPS, to facilitate signal distribution and solenoid control.