General Electric IC200EBI001 VersaMax Ethernet Network Interface Unit

General Electric IC200EBI001 VersaMax Ethernet Network Interface Unit

The IC200EBI001 is a VersaMax Ethernet Network Interface Unit (ENIU) designed to facilitate distributed I/O architecture within industrial control systems. This module acts as an Ethernet slave, managing communication between...

25 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 3

SKU: IC200EBI001
Proveedora: General Electric

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The IC200EBI001 is a VersaMax Ethernet Network Interface Unit (ENIU) designed to facilitate distributed I/O architecture within industrial control systems. This module acts as an Ethernet slave, managing communication between the host controller and local I/O modules. It supports standard Ethernet connectivity, allowing for integration into various automation networks.

Features

  • Serves as a high-performance Network Interface Unit (NIU) for the VersaMax I/O family.
  • Supports 10/100 Mbps Ethernet communication with auto-negotiation.
  • Configurable via rotary switches (X1, X10, X100) for IP address assignment or via ARP commands.
  • Supports up to 1024 bytes of total I/O data (512 bytes input / 512 bytes output).
  • Scalable architecture: Supports up to 8 modules (Release 1.0) or up to 64 modules with 7 expansion racks (Release 1.1 and later).
  • Integrated LED diagnostics for PWR, OK, FAULTS, LAN, and STAT status monitoring.

Applications

  • Water treatment and municipal wastewater management systems.
  • Oil and gas production, refining, and distribution automation.
  • Power and energy management, including generator and transformer monitoring.
  • Intelligent machinery manufacturing and industrial furnace control.

Technical Specifications

Model IC200EBI001
Manufacturer General Electric
Communication Port 1 x RJ45 Ethernet
Transmission Rate 10/100 Mbps (Auto-negotiation)
Transmission Media Ethernet Twisted Pair
Max Drop Length 100 meters
I/O Capacity Up to 64 modules (firmware dependent)
Indicators PWR, OK, FAULTS, LAN, STAT
Tariff Code 8537101190

Installation Guidelines

  • Mount the unit on a 35mm x 7.5mm conductive, unpainted DIN rail to ensure proper chassis grounding.
  • Ensure the side connector cover remains in place on the last carrier to protect internal pins from ESD and physical damage.
  • Verify the power supply locking latch is in the "locked" position during operation to prevent intermittent power loss.
  • Maintain recommended environmental clearances around the module to prevent overheating and ensure rated thermal performance.
  • Always power down the system before inserting or removing I/O modules to prevent electrical damage.

FAQ

What is the primary function of the IC200EBI001?

The IC200EBI001 is an Ethernet Network Interface Unit that allows VersaMax I/O modules to communicate over an Ethernet network, enabling distributed I/O control.

How is the IP address configured?

The module features three rotary switches (X1, X10, X100) for manual IP address assignment. Alternatively, the IP address can be configured via the DOS command prompt using the arp-s command.

Does the module support auto-configuration?

Yes, the module performs an auto-configuration sequence upon power-up, identifying connected I/O modules until an empty slot or fault is detected.