Ir directamente a la información del producto
1 de 3

Honeywell GA-USB1-IR Infrared Connectivity Kit for BW Portable Gas Detectors

Honeywell GA-USB1-IR Infrared Connectivity Kit for BW Portable Gas Detectors

The Honeywell GA-USB1-IR is a dedicated USB-to-infrared connectivity kit engineered for the configuration, data retrieval, and maintenance of Honeywell BW portable gas detectors. This hardware solution facilitates wireless communication between...

15 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 5

SKU: GA-USB1-IR
Proveedora: Honeywell

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The Honeywell GA-USB1-IR is a dedicated USB-to-infrared connectivity kit engineered for the configuration, data retrieval, and maintenance of Honeywell BW portable gas detectors. This hardware solution facilitates wireless communication between the gas monitor and a PC, streamlining the process of downloading critical safety data and updating instrument parameters without the need for physical cable connections to the detector's internal circuitry.

Features

  • Official Honeywell BW IR connectivity hardware
  • Enables seamless data transfer for alarm histories, gas exposure logs, and calibration records
  • Supports instrument configuration, including alarm setpoints and sensor parameters
  • Compact, portable design suitable for both field and workshop environments
  • Powered via USB interface; no external power supply required

Applications

  • Oil, Gas, and Petrochemical: Verification of exposure logs and compliance reporting following site operations.
  • Confined Space Entry: Regular maintenance and bump-test record-keeping for worker safety audits.
  • Industrial Safety: Centralized management of alarm thresholds and sensor configurations across large detector fleets.
  • Calibration Management: Facilitates the clearing of IR-locked calibration states and provides a digital trail for regulatory compliance.

Technical Specifications

Model GA-USB1-IR
Interface USB Type-A
Communication Infrared (IR)
Current Draw < 100 mA
Operating Temperature 0 degC to +50 degC
Storage Temperature -20 degC to +60 degC
Humidity 0% to 95% RH (non-condensing)
Cable Length 1.5 to 2 meters

Installation Guidelines

  • Software Setup: Download and install the latest version of Honeywell Safety Suite Device Configurator or Fleet Manager II from the official Honeywell website to ensure compatibility with modern Windows operating systems.
  • Connection: Connect the USB-A end of the cable to your PC. Ensure the drivers are correctly recognized by the operating system.
  • Alignment: Position the IR dongle cap directly over the infrared communication port on the front of the compatible BW gas detector. Ensure the path between the dongle and the detector is clear of obstructions.
  • Handling: The IR link is a precision optical device; keep the infrared lens clean and free of debris to maintain reliable data transmission.

FAQ

Which gas detectors are compatible with the GA-USB1-IR?

The kit is compatible with most Honeywell BW portable monitors, including the GasAlertMicroClip series (XT/XL/X3), GasAlertMax XT II, GasAlertQuattro, BW Ultra, BW Flex, and BW Icon series.

What software is required for operation?

The kit is designed for use with Honeywell Fleet Manager II or the current Safety Suite Device Configurator software to manage device settings and extract diagnostic logs.

What should I do if the computer does not recognize the device?

Verify that the USB cable is securely connected to a functional USB port. Ensure the appropriate device drivers are installed and that the Honeywell software is active and set to the correct communication mode.