Honeywell FS-TSGAS-1624 Safety Systems Gas and Flame Detector Input Field Termination Assembly

Honeywell FS-TSGAS-1624 Safety Systems Gas and Flame Detector Input Field Termination Assembly

The Honeywell FS-TSGAS-1624 is a 16-channel Fail-Safe Gas and Flame Detector Input Field Termination Assembly (FTA) designed for integration with Honeywell Safety Manager safety instrumented systems. This module serves as...

28 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 3

SKU: FS-TSGAS-1624
Proveedora: Honeywell

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The Honeywell FS-TSGAS-1624 is a 16-channel Fail-Safe Gas and Flame Detector Input Field Termination Assembly (FTA) designed for integration with Honeywell Safety Manager safety instrumented systems. This module serves as a critical interface between field-mounted gas detectors, flame detectors, and the SAI-1620m safe analog input module, ensuring reliable signal acquisition for safety-critical applications.

Features

  • 16-channel analog input interface for gas and flame detectors.
  • Supports standard 0–20 mA and 4–20 mA input signals.
  • Provides linear conversion of field signals to levels required by the SAI-1620m module.
  • Integrated per-channel 500 mAT fuse for transmitter power protection.
  • Supports HART communication for advanced diagnostic and configuration capabilities.
  • Universal snap-in mounting for standard DIN EN rails.

Applications

  • Emergency Shutdown Systems (ESD): Triggers facility shutdown upon detection of hazardous gas or flame conditions.
  • Fire and Gas (F&G) Systems: Provides a robust input interface for combustible/toxic gas and flame monitoring sensors.
  • Critical Process Protection: Processes 0-20 mA safety signals within the Honeywell Safety Manager architecture.
  • Turbomachinery: Supports control and protection loops for large-scale turbines and compressors.
  • Pipeline Infrastructure: Facilitates leak monitoring across extensive industrial pipeline networks.

Technical Specifications

Product Model FS-TSGAS-1624
Input Channels 16
Input Current 0–25 mA
Input Resistance 500 Ohm (± 5%)
Output Voltage 0–4 V DC
Accuracy 0.1%
Fuse Rating 500 mAT (per channel)
Voltage Rating (AC) 250 V
Voltage Rating (DC) 300 V
Power Requirements 24 V DC, 3 mA

Installation Guidelines

  • Mount the FTA securely on standard DIN EN rails (TS32 or TS35 x 7.5).
  • Ensure a minimum rail length of 226 mm to accommodate the module footprint.
  • Use the dedicated terminal on each channel for field cable shield termination to minimize EMI.
  • Verify power supply polarity and connections before energizing the system.
  • Always power down the system before inserting or removing the module to prevent electrical damage.
  • Ensure adequate ventilation in the cabinet to maintain operating temperature limits.

FAQ

What is the primary function of the FS-TSGAS-1624?

It acts as a 16-channel interface that converts 0(4)-20 mA analog field signals from gas and flame detectors into the signal levels required by the SAI-1620m high-density analog input module.

Is this module compatible with HART communication?

Yes, the module supports HART communication, allowing for advanced device diagnostics and configuration of connected field instruments.

How are the field transmitters protected?

Each analog input channel is equipped with an individual 500 mAT fuse to protect the power supply to the field transmitter.