Ir directamente a la información del producto
1 de 3

ProSoft MVI56-HART ControlLogix HART Master Module

ProSoft MVI56-HART ControlLogix HART Master Module

Description

The ProSoft MVI56-HART is a 4-channel HART Master Multi-drop Network Interface Module designed for integration with the Rockwell Automation ControlLogix platform. This module facilitates bi-directional communication between ControlLogix processors and...

23 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 1

SKU: MVI56-HART
Proveedora: Prosoft

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The ProSoft MVI56-HART is a 4-channel HART Master Multi-drop Network Interface Module designed for integration with the Rockwell Automation ControlLogix platform. This module facilitates bi-directional communication between ControlLogix processors and HART-compatible field instruments, providing essential access to secondary digital variables and device diagnostics. By enabling real-time asset management and predictive maintenance, the MVI56-HART helps reduce unplanned downtime and optimizes calibration cycles in demanding industrial process control applications.

Features

  • Four independent HART channels supporting both point-to-point and multi-drop network topologies.
  • FSK digital signal processing allows for simultaneous analog 4-20 mA monitoring and digital data extraction.
  • Offloads protocol framing, timing, and error checking from the ControlLogix CPU to ensure efficient system performance.
  • Integrated status LEDs for backplane activity, error status, and individual channel communication monitoring.
  • Direct backplane compatibility with ControlLogix chassis for seamless integration.

Applications

The MVI56-HART is widely utilized in process-intensive industries including oil and gas refineries, chemical processing plants, and large-scale water treatment facilities where smart instrumentation diagnostics are required for operational efficiency.

Technical Specifications

Model MVI56-HART
Brand ProSoft Technology
Product Type HART Master Multi-drop Communication Module
Channels 4 Independent HART Channels
Network Support Point-to-point or Multi-drop
Backplane Current Load 800 mA at 5.1 VDC
Operating Temperature 0 to 60 deg C
Storage Temperature -40 to 85 deg C
Relative Humidity 5 to 95 percent (non-condensing)

Installation Guidelines

  • Ensure the ControlLogix chassis power is removed before inserting or removing the module.
  • The module is designed for standard ControlLogix rack mounting; ensure the module is fully seated and the locking tab is engaged.
  • Use appropriate shielded cabling for HART communication to minimize EMI interference.
  • Maintain proper ventilation within the cabinet to ensure operating temperatures remain within the 0 to 60 deg C range.
  • Follow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.

FAQ

What is the primary function of the MVI56-HART?

The MVI56-HART acts as a gateway between HART-enabled field devices and the ControlLogix controller, allowing the PLC to read digital process variables and diagnostic data from the instruments without interrupting the analog 4-20 mA signal.

Does this module require external power?

The module draws its power directly from the ControlLogix backplane (800 mA at 5.1 VDC). No external power supply is required for the module itself, though field instruments will require their own loop power.