Ir directamente a la información del producto
1 de 3

ProSoft MVI56-MCMR Modbus Master/Slave Communication Module for ControlLogix

ProSoft MVI56-MCMR Modbus Master/Slave Communication Module for ControlLogix

Description

The ProSoft MVI56-MCMR is a specialized Modbus Master/Slave communication module designed for the Rockwell Automation ControlLogix platform. It is specifically optimized for remote chassis applications, such as those utilizing ControlNet,...

22 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 7

SKU: MVI56-MCMR
Proveedora: ProSoft

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The ProSoft MVI56-MCMR is a specialized Modbus Master/Slave communication module designed for the Rockwell Automation ControlLogix platform. It is specifically optimized for remote chassis applications, such as those utilizing ControlNet, where bandwidth optimization is critical. By utilizing a reduced 42-word Input/Output image, the MVI56-MCMR minimizes bandwidth impact compared to standard modules, making it an ideal choice for complex, distributed control systems.

Features

  • Optimized for Remote Racks: Designed for ControlNet and remote chassis environments to reduce bandwidth consumption.
  • Dual Serial Ports: Features two configurable serial ports supporting RS-232, RS-422, and RS-485 physical standards.
  • Flexible Baud Rates: Supports communication speeds ranging from 110 baud up to 115,200 baud.
  • Configuration: Configured via ProSoft Configuration Builder (PCB) with integration into RSLogix 5000 using Add-On Instructions (AOI).
  • Visual Diagnostics: Integrated LED indicators provide real-time status updates for communication and module health.

Applications

  • Oil and Gas: Data acquisition for pipelines and offshore platform monitoring.
  • Water and Wastewater: Managing data exchange between control systems and remote monitoring stations.
  • Food Processing: Integration of automated production line equipment.
  • Mining, Pulp, and Paper: Connecting legacy serial equipment to modern ControlLogix architectures.

Technical Specifications

Model MVI56-MCMR
Backplane Current (5 VDC) 800 mA
Backplane Current (24 VDC) 3 mA
Operating Temperature 0 to 60 degC
Slot Requirements 1 Slot
Communication Standards RS-232, RS-485, RS-422
Baud Rate 110 to 115,200 bps
I/O Mapping 42-word reduced image

Installation Guidelines

  • Power Off: Always remove power from the ControlLogix chassis before inserting or removing the module to prevent electrical damage.
  • Slot Placement: The module occupies one slot in the ControlLogix rack. Ensure it is seated firmly and the locking tab is engaged.
  • Jumper Configuration: Physical serial standards (RS-232/422/485) are selected via jumpers located at the bottom of the module. Ensure these are set correctly before installation.
  • Wiring: Use a minimum phase wire size of 1.3 mm squared. Ensure proper shielding for serial cables to minimize EMI in industrial environments.
  • Grounding: Follow standard industrial grounding practices for the chassis to ensure signal integrity.

FAQ

What is the primary difference between MVI56-MCM and MVI56-MCMR?

The MVI56-MCMR is optimized for remote chassis applications by using a reduced 42-word I/O image to save bandwidth, whereas the MVI56-MCM uses a larger 250-word image. Additionally, the MCMR does not support the Modbus Pass-Thru feature.

How is the module configured?

The MVI56-MCMR is configured using an offline file created in ProSoft Configuration Builder (PCB) and integrated into the processor using Add-On Instructions (AOI) within RSLogix 5000.

Can I prevent data loss during a power cycle?

Yes, you can use the Initialize Input Image parameter to cache values from the processor so they are not reset to zero during a module reset or power loss.