The ProSoft MVI69-DFNT is a high-performance communication module designed to provide EtherNet/IP connectivity for Rockwell Automation CompactLogix and MicroLogix 1500 LRP platforms. Acting as a bridge within the 1769 backplane,...

29 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 7

SKU: MVI69-DFNT
Proveedora: Prosoft

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The ProSoft MVI69-DFNT is a high-performance communication module designed to provide EtherNet/IP connectivity for Rockwell Automation CompactLogix and MicroLogix 1500 LRP platforms. Acting as a bridge within the 1769 backplane, this module facilitates robust data exchange between the PLC and external EtherNet/IP-enabled devices. It supports both client and server operations, allowing for flexible integration into complex industrial automation architectures, including manufacturing, material handling, and process control systems.

Features

  • Backplane Integration: Designed specifically for the 1769 CompactLogix backplane, occupying a single slot.
  • Protocol Support: Acts as an EtherNet/IP Client/Server interface, supporting explicit messaging for efficient data transfer.
  • Command Capacity: Supports up to 100 user-configurable commands for read/write operations to remote network devices.
  • Server Functionality: Includes 20 server connections to handle requests from external network equipment.
  • Processor Compatibility: Compatible with a wide range of CompactLogix processors (L20, L30, L31, L32, L35) and L43/L45 models (requires RSLogix 5000 v16.03 or later).
  • Legacy Support: Fully compatible with MicroLogix 1500 LRP controllers.

Applications

The MVI69-DFNT is ideal for industrial environments requiring reliable network isolation and dedicated communication ports. It is commonly used to integrate third-party EtherNet/IP devices, manage network traffic, and extend the communication capabilities of existing CompactLogix control systems.

Technical Specifications

Model MVI69-DFNT
Brand ProSoft Technology
Power Requirement 800 mA at 5 VDC
Slot Width Single Slot
Operating Temperature 0 to 60 deg C
Communication Protocol EtherNet/IP (Explicit Messaging)
Max Commands 100 Configurable
Server Connections 20

Installation Guidelines

  • Power Down: Always remove power from the 1769 backplane before installing or removing the module to prevent electrical damage.
  • Seating: Ensure the module is properly aligned with the backplane connector and fully seated in the slot. Secure the module using the integrated locking mechanism.
  • Grounding: Follow standard industrial grounding practices for the 1769 system to minimize electrical noise and EMI interference.
  • Wiring: Use shielded Ethernet cabling for network connections to maintain signal integrity in high-EMI industrial environments.
  • ESD Handling: Use an anti-static wrist strap or similar ESD protection when handling the module to prevent damage to sensitive internal components.

FAQ

Does the MVI69-DFNT require special software for configuration?

The module is typically configured using ProSoft Configuration Builder (PCB) software, which allows you to define the communication parameters and command lists required for your specific application.

Can this module be used in a remote I/O rack?

The MVI69-DFNT is designed for use in the local 1769 backplane of a CompactLogix controller. It is not intended for use in remote I/O chassis.