Schneider Modicon DEA 156 Bitbus Receiver Module (6051-042.270383)

Schneider Modicon DEA 156 Bitbus Receiver Module (6051-042.270383)

Description

The DEA 156 (DEA156) is a specialized Bitbus-I/O receiver module developed for the legacy AEG Modicon Logistat automation line, now supported under the Schneider Electric portfolio. This module functions as...

25 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 2

SKU: DEA 156
Proveedora: Schneider

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The DEA 156 (DEA156) is a specialized Bitbus-I/O receiver module developed for the legacy AEG Modicon Logistat automation line, now supported under the Schneider Electric portfolio. This module functions as a high-speed communication link interface, managing data routing and synchronization across distributed Bitbus networks. By establishing deterministic serial fieldbus connections between central automation processors and peripheral field drops, the DEA 156 maintains precise operational timing even in environments subject to high electromagnetic interference. It is designed to minimize communication errors and packet bottlenecks, preventing system lockouts and reducing unplanned downtime in legacy industrial applications.

Features

  • High-speed serial communication interface for Bitbus network protocols.
  • Integrated optocouplers provide robust galvanic isolation between the bus and internal logic circuits.
  • Front-panel LED diagnostic array for real-time monitoring of network activity, error states, and power health.
  • Engineered for deterministic data transmission in distributed control architectures.
  • Standardized rack-mount form factor for seamless integration into legacy Modicon chassis.

Applications

The DEA 156 is primarily utilized in vintage industrial process control systems requiring reliable Bitbus communication. Typical applications include petrochemical refining plants, metallurgical processing lines, and thermal power generation facilities where legacy Modicon Logistat infrastructure remains in operation.

Technical Specifications

Model DEA 156
Part Number 6051-042.270383
Brand Schneider Electric (Legacy AEG Modicon)
Product Type Bitbus-I/O Receiver Module
Communication Protocol Bitbus
Power Consumption 5.5 W maximum
Operating Temperature 0 to 60 deg C
Storage Temperature -40 to 85 deg C
Relative Humidity 95 % maximum (non-condensing)
Certifications CE, UL, CSA

Installation Guidelines

  • Ensure the industrial chassis rack is properly grounded before module insertion to prevent ESD damage.
  • Always power down the rack backplane before installing or removing the module to prevent electrical arcing or logic corruption.
  • Ensure the module is fully seated in the designated backplane slot to maintain reliable bus contact.
  • Route communication cabling away from high-voltage power lines and sources of high-EMI to maintain signal integrity.
  • Verify that the front-panel LEDs indicate normal operation status after power-up; consult the diagnostic array if error indicators persist.

FAQ

What is the primary function of the DEA 156 module?

The DEA 156 acts as a Bitbus receiver, facilitating deterministic serial communication between central controllers and remote I/O drops within the Modicon Logistat system.

Can this module be used in high-EMI environments?

Yes, the module is designed for industrial environments and features optocoupler-based galvanic isolation to protect internal logic from electrical surges and noise on the bus lines.

What should I do if the error LED is illuminated?

Check the physical integrity of the Bitbus cabling, ensure the bus is terminated correctly, and verify that the module is properly seated in the rack. If the error persists, check the master controller status for communication timeout logs.