Ir directamente a la información del producto
1 de 3

Schneider Electric NWRR85001 Modicon Communication Module

Schneider Electric NWRR85001 Modicon Communication Module

Description

The Schneider Electric NWRR85001 is a specialized communication interface module designed for the Modicon automation ecosystem. It functions as a robust gateway for industrial networking, facilitating reliable data exchange between...

17 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 4

SKU: NWRR85001
Proveedora: Schneider

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The Schneider Electric NWRR85001 is a specialized communication interface module designed for the Modicon automation ecosystem. It functions as a robust gateway for industrial networking, facilitating reliable data exchange between field-level devices and higher-level control systems. This module is engineered to maintain deterministic communication in demanding industrial environments, including power generation, petrochemical processing, and heavy manufacturing, where signal integrity and network uptime are critical to operational safety.

Features

  • Dual redundant physical media ports supporting ring or star network topologies for high availability.
  • Integrated isolation circuitry to suppress common-mode voltage interference.
  • Concurrent support for industrial protocols including Modbus TCP and Ethernet/IP.
  • Hardware-level packet prioritization to minimize latency on the CPU backplane.
  • Real-time network health diagnostics to proactively identify communication degradation.

Applications

This communication module is suitable for distributed control architectures where reliable, noise-immune data transmission is required. It is commonly deployed in hazardous area processing zones, thermal power plants, and mining infrastructure to bridge physical network layers and prevent system-wide communication failures.

Technical Specifications

Model NWRR85001
Brand Schneider Electric
Operating Temperature -25 to 70 deg C
Power Consumption 550 mA at 24 VDC (13.2 W max)
Network Interfaces Dual RJ-45 10/100 Mbps copper Ethernet
Isolation Voltage 1500 V RMS
Data Rate 10/100 Mbps (auto-negotiation)

Installation Guidelines

  • Ensure the module is installed in a clean, dry, and vibration-dampened enclosure suitable for the application environment.
  • Always disconnect the 24 VDC power supply before inserting or removing the module from the rack to prevent electrical arcing or damage to the backplane pins.
  • Use shielded Ethernet cabling for all network connections to maintain EMI immunity, especially in high-noise industrial zones.
  • Ensure proper grounding of the module chassis to the system common ground to facilitate effective surge and noise suppression.
  • Verify that the ambient temperature within the cabinet does not exceed the specified 70 deg C limit to ensure long-term component reliability.

FAQ

Does this module support redundant network configurations?

Yes, the NWRR85001 features dual physical media ports that support ring or star topologies, allowing for instantaneous recovery paths in the event of a cable break.

What is the primary function of the NWRR85001?

It acts as a deterministic communication gateway for the Modicon platform, managing protocol transactions and network health monitoring to ensure stable data flow between distributed control nodes.