SMART Transmitter Power Supply Yokogawa KFD2-STC4-1

SMART Transmitter Power Supply Yokogawa KFD2-STC4-1

Configured for signal conditioning in industrial networks, the Yokogawa KFD2-STC4-1 (KFD2-STC4-1 SMART Transmitter Power Supply) provides direct physical/electrical execution of signal isolation and transmitter power distribution.

Hardware Specifications

...
26 la gente está viendo esto ahora mismo

DisponibilidadEn existencias

SKU: KFD2-STC4-1
Proveedora: Yokogawa

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Configured for signal conditioning in industrial networks, the Yokogawa KFD2-STC4-1 (KFD2-STC4-1 SMART Transmitter Power Supply) provides direct physical/electrical execution of signal isolation and transmitter power distribution.

Hardware Specifications

Parameter Specification
Model KFD2-STC4-1
Brand Yokogawa
Origin Germany
Weight 0.15 kg
Dimensions 20 mm x 119 mm x 115 mm
Operating Temp -20 deg C to 60 deg C
Power Consumption 24 VDC (via Power Rail)
Input 2-wire / 3-wire SMART transmitters
Output 0/4-20 mA current
Safety Rating SIL2 acc. to IEC 61508

Intrinsic Safety and Network Signal Conditioning

The KFD2-STC4-1 incorporates intrinsic safety (Ex i) barriers to ensure safe operation in hazardous area loops. These barriers limit the electrical energy transmitted to the field instrumentation, preventing ignition sources in volatile atmospheres. The module provides galvanic isolation between the input and output circuits, eliminating ground loops that often degrade signal accuracy in long-run industrial cabling. Furthermore, the unit facilitates protocol transparency for SMART transmitters, allowing bidirectional digital communication to pass through the 4-20 mA loop without attenuation or loss of HART data packets.

Frequently Asked Questions

Q: Does the KFD2-STC4-1 support DIN-rail mounting stability?

A: Yes. The housing is designed for snap-on mounting onto a 35 mm DIN mounting rail. For high-vibration applications, ensure the unit is fully seated and locked into the rail profile to maintain electrical connectivity via the Power Rail system.

Q: Is the output signal capable of driving external loads while maintaining HART transparency?

A: Yes. The output is a standard 0/4-20 mA active or passive current source. It is designed to accommodate the typical load impedance requirements of DCS or PLC analog input cards while preserving the integrity of the superimposed HART communication frequency.

Field Installation Guidelines

  • Mounting: Ensure the module is installed in a vertical orientation to facilitate proper convective airflow. Use the integrated Power Rail connector for simplified 24 VDC power distribution.
  • Wiring: Use shielded twisted-pair cables for input and output connections to mitigate electromagnetic interference. Ground the cable shield at one point only—typically at the control system side—to prevent circulating ground currents.
  • Termination: Utilize the provided test points on the front terminal block for loop current verification without disconnecting field wires. Ensure terminal screw torque is maintained at manufacturer-specified levels (typically 0.5 Nm) to prevent loose connections.
  • Segregation: Maintain strict physical separation between intrinsically safe (blue) terminal wiring and non-intrinsically safe wiring to prevent fault propagation.