Ir directamente a la información del producto
1 de 2

SNB10D-425/CU2T Yokogawa Safety Node Unit | New & Original Stock

SNB10D-425/CU2T Yokogawa Safety Node Unit | New & Original Stock

Configured for safety-critical monitoring and control in ProSafe-RS SIS platforms, the Yokogawa SNB10D-425/CU2T (SNB10D Safety Node Unit) provides direct physical/electrical execution of safety logic and I/O communication within the safety...

26 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 99

SKU: SNB10D-425/CU2T
Proveedora: Yokogawa
Related Series:

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Configured for safety-critical monitoring and control in ProSafe-RS SIS platforms, the Yokogawa SNB10D-425/CU2T (SNB10D Safety Node Unit) provides direct physical/electrical execution of safety logic and I/O communication within the safety instrumented system architecture.

Suffix Breakdown & Model Matrix

The SNB10D-425/CU2T model identifier is structured to denote specific hardware capabilities and environmental hardening:

  • SNB10D: Base Safety Node Unit model series.
  • -425: Encodes the combined power supply and environmental specifications; "4" indicates 220 to 240 V AC input, "2" indicates dual-redundant power capability with R3 node expansion support, and "5" denotes ISA Standard G3 gas-corrosion resistance with an extended operating temperature range of -20 deg C to 70 deg C.
  • CU2T: Specifies the inclusion of the S9342FA connector unit for ESB bus communication.

Hardware Specifications

Parameter Specification
Model SNB10D-425/CU2T
Brand Yokogawa
Origin Japan
Weight 5.9 kg
Dimensions 20.5 cm x 48.2 cm x 22.1 cm
Operating Temp -20 deg C to 70 deg C
Power Consumption Dual-redundant 220-240 V AC
Safety Compliance SIL3 capable architecture

Safety SIS and Galvanic Isolation

The SNB10D-425 utilizes a triple modular redundancy (TMR) 2oo3 architecture to facilitate fail-safe state execution in the event of an internal hardware fault. To maintain signal integrity and safety, the unit incorporates galvanic isolation across I/O channels. This electrical separation prevents ground loops and ensures that common-mode interference does not compromise the logic-solving capabilities of the safety node, adhering to strict SIL3 certification requirements for industrial hazardous environments.

Frequently Asked Questions (FAQ)

Q: Does the SNB10D-425 support hot-swapping of I/O modules during operation?

A: Yes, the node unit is designed to support the hot-swap of individual I/O modules within the rack without interrupting the safety bus communication, provided the local safety application is configured to handle the transient state of the module removal.

Q: What is the significance of the ISA Standard G3 rating for this unit?

A: The G3 rating signifies that the hardware components are engineered to withstand severe environments characterized by corrosive gas exposure. This environmental hardening prevents premature degradation of internal circuits, which is required for long-term safety function performance.

Field Installation Guidelines

  • Ensure the node unit is mounted in a cabinet that provides adequate ventilation, as the power supply modules generate heat during continuous operation.
  • Confirm that the protective earth (PE) connection is firmly secured to the cabinet ground bus to maintain the effectiveness of the EMI shielding.
  • Use only the designated S9342FA connector cables for ESB bus integration; ensure connectors are fully seated and locked to prevent intermittent communication errors.
  • Before applying power, verify that the AC input voltage matches the range defined by the "4" suffix (220-240 V AC) to avoid damage to the power supply units.