WOODWARD 9907-1200 Pressure Regulating Valve Control

WOODWARD 9907-1200 Pressure Regulating Valve Control

The WOODWARD 9907-1200, also cataloged as the 9907-1200 Pressure Regulating Valve Control, operates as a dedicated hardware component for closed-loop valve positioning and pressure loop execution within turbine liquid or...

23 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 6

SKU: 9907-1200
Proveedora: Woodward

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

The WOODWARD 9907-1200, also cataloged as the 9907-1200 Pressure Regulating Valve Control, operates as a dedicated hardware component for closed-loop valve positioning and pressure loop execution within turbine liquid or gas delivery systems.

Hardware Specifications

Parameter Specification
Model 9907-1200
Brand WOODWARD
Origin USA
Weight 4.45 kg
Dimensions 35.8 x 28.2 x 9.5 cm
Operating Temp -40 to 70 deg C
Power Consumption 24 VDC nominal (18 to 32 VDC operational range)
Product Type Pressure Regulating Valve Control
Control Interface Closed-loop electro-hydraulic / electro-mechanical valve driver

Actuator Loop Feedback Response and Thermal Dissipation

The control electronics sample valve position feedback and line pressure signals to dynamically calculate drive currents for the pressure regulating valve driver. Internal stabilization algorithms maintain tight control over actuator loop feedback response, eliminating mechanical pressure overshoot during sudden hydraulic load variations. Internal driver stages utilize the heavy-duty enclosure as an integral heat sink, managing thermal heat sink dissipation profiles during continuous high-current valve actuation.

Frequently Asked Questions

Q: How does the unit process pressure feedback signals to prevent valve hunting?

A: The internal processing circuits apply dynamic lag-lead filtering and proportional-integral loop calculations to stabilize actuator loop feedback response, dampening high-frequency pressure spikes and preventing control loop oscillations.

Q: What are the primary grounding requirements for input pressure transducer wiring?

A: All pressure sensor and valve feedback lines must use twisted-shielded pair conductors with the cable shield terminated at a single point on the control unit chassis ground terminal to avoid ground loop current interference.

Field Installation Guidelines

  1. Mount the 35.8 x 28.2 x 9.5 cm chassis securely on a flat vertical mounting plate using all four corner mounting holes to handle mechanical vibration.
  2. Ensure the main 24 VDC power supply feed is protected by an appropriately rated inline fuse or circuit breaker before energizing the module.
  3. Route low-level pressure transducer wiring through grounded metal conduit separate from high-current actuator drive lines.
  4. Connect the main chassis ground terminal to the local protective earth grid using a short, heavy-gauge copper grounding jumper.
  5. Maintain a minimum surrounding air clearance of 50 mm around the enclosure housing to ensure uninhibited heat dissipation.