Woodward 9907-345 Overspeed Trip Device

Woodward 9907-345 Overspeed Trip Device

Configured for high-speed rotational speed monitoring and emergency shutdown execution in turbine protection networks, the Woodward 9907-345 (9907-345 Overspeed Trip Device) provides direct physical/electrical execution. The hardware continuously monitors prime...

20 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 6

SKU: 9907-345
Proveedora: Woodward

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Configured for high-speed rotational speed monitoring and emergency shutdown execution in turbine protection networks, the Woodward 9907-345 (9907-345 Overspeed Trip Device) provides direct physical/electrical execution. The hardware continuously monitors prime mover shaft velocity via magnetic pickup sensors, driving immediate trip relay activation to cut fuel supply upon detecting speed values exceeding pre-programmed safety thresholds.

Hardware Specifications

Parameter Specification
Model 9907-345
Brand Woodward
Origin USA
Weight 3.2 kg
Dimensions 17.8 cm x 19.1 cm x 19.7 cm
Operating Temp -40 deg C to +70 deg C
Power Consumption Standard 24 VDC Control Loop Power
Product Type Overspeed Trip Devices
Functional Core Microprocessor-Based Speed Protection
Sensor Inputs Magnetic Speed Pickup Inputs
Output Stage High-Speed Emergency Trip Relays

Actuator Loop Feedback Response Dynamics

The overspeed protection module utilizes high-speed frequency decoding algorithms to optimize actuator loop feedback response during critical load rejection events. Upon detecting an acceleration rate or absolute velocity crossing the emergency trip limit, the device executes trip contact state changes in under 15 ms. This rapid output response de-energizes trip solenoids and fuel stop valves instantly, preventing catastrophic mechanical overspeed damage and restoring the system to a fail-safe state.

Frequently Asked Questions

Q: How does the device prevent false trips caused by electrical noise on the speed pickup lines?

A: The input channels incorporate high-frequency noise filtering and variable-threshold peak detection circuits, ensuring only true gear-tooth signal transitions trigger speed calculation logic.

Q: What is the trip contact execution time when an overspeed event occurs?

A: The onboard micro-controller and high-speed output relays process trip state conditions and drop relay contacts in less than 15 ms from signal threshold breach.

Q: Is external power required to maintain protective speed monitoring function?

A: The device requires a continuous 24 VDC auxiliary power supply to drive processing circuits and internal trip relay coils in an energized-to-run configuration.

Field Installation Guidelines

  1. Mount the heavy-duty enclosure securely to a vertical panel or structural frame inside a NEMA 12 or IP54 rated control cabinet using standard mounting hardware.
  2. Establish a low-impedance earth ground connection from the chassis ground terminal to the main system earth bus using a 10 AWG braided strap.
  3. Wire magnetic pickup inputs using individually shielded twisted-pair cables, grounding the cable shield drain wire at the trip device terminal end only.
  4. Route emergency trip output wiring to the fuel shutoff solenoid using stranded 14 AWG conductors, separated from high-voltage AC lines by at least 200 mm.
  5. Perform a simulated frequency test across the input terminals to verify trip setpoint accuracy and relay contact action prior to final system commissioning.