Ir directamente a la información del producto
1 de 3

Yokogawa AAR145-S00 S1 RTD/POT Input Module

Yokogawa AAR145-S00 S1 RTD/POT Input Module

Description

The Yokogawa AAR145-S00 S1 is a high-density, 16-channel analog input module designed for the CENTUM series control systems. This module is specifically engineered to process RTD (Resistance Temperature Detector) and...

28 la gente está viendo esto ahora mismo

DisponibilidadBajas existencias: quedan 3

SKU: AAR145-S00 S1
Proveedora: Yokogawa

Envíos y devoluciones

Entrega confiable a nivel mundial

  • Transportistas: Envíos a través de DHL, FedEx, UPS o USPS .
  • Envío: Los pedidos se procesan en 1-2 días hábiles y se envían dentro de 3-5 días hábiles .
  • Seguimiento: Detalles completos de seguimiento proporcionados por correo electrónico después del envío.

Garantía de devolución de dinero de 30 días

  • Garantía: período de devolución de 30 días para productos en stock y sellados de fábrica.
  • Condición: Los artículos deben estar sin abrir, sin usar y en su embalaje original.
  • Autenticidad: Garantizamos hardware 100% original y auténtico.

¿Necesitas más información? Consulta nuestra Política de envíos y reembolsos completa.

Autenticidad y garantía

  • Garantía genuina: Suministramos únicamente piezas de automatización industrial 100% originales, nuevas y selladas de fábrica .
  • Cobertura total: cada componente está respaldado por una garantía integral de 12 meses a partir de la fecha de compra.
  • Trazabilidad: Todos los productos se entregan con documentación original de fábrica y accesorios para un pleno cumplimiento industrial.

Soporte técnico y abastecimiento

  • Asistencia de expertos: Nuestro equipo técnico ofrece consulta gratuita para ayudarle a verificar la compatibilidad de los sistemas DCS y PLC.
  • Abastecimiento de piezas raras: nos especializamos en componentes obsoletos y difíciles de encontrar de Allen-Bradley, Siemens, ABB, HIMA y más.
  • Consultas al por mayor: contáctenos en pambo@5gplc.com para obtener precios por volumen o cotizaciones de proyectos personalizados.
Ver todos los detalles

Description

The Yokogawa AAR145-S00 S1 is a high-density, 16-channel analog input module designed for the CENTUM series control systems. This module is specifically engineered to process RTD (Resistance Temperature Detector) and Potentiometer (POT) signals, providing isolated inputs for reliable data acquisition in industrial process control environments.

Features

  • 16 isolated input channels for enhanced signal integrity.
  • Supports JIS C1604:1997 and IEC751:1995 Pt100 (3-wire) RTD inputs.
  • Configurable for Potentiometer inputs with total resistance ranges from 100 Ohm to 10 kOhm.
  • Individual channel configuration for RTD or POT signal types.
  • Integrated burn-out detection with configurable UP/DOWN settings.
  • High withstanding voltage isolation between channels and system.

Applications

This module is widely used in process automation systems where precise temperature monitoring or position feedback is required. Typical applications include thermal management systems, valve position monitoring, and critical process measurement loops within the Yokogawa CENTUM distributed control system architecture.

Technical Specifications

Item Specification
Number of input channels 16, isolated
Input signal RTD (Pt100 3-wire), POT (100 Ohm to 10 kOhm)
Accuracy RTD: +/-150 mOhm; POT: +/-0.2 %/FS
Measurement current RTD: 1 mA
Data update period 1 s
Burn-out detection Configurable (UP/DOWN); 60 s detection time
Current consumption 350 mA (5 V DC)
External connection Dedicated cable (KS8/AKB335)

Installation Guidelines

  • Ensure the control system is powered down before inserting or removing the module from the rack.
  • Handle the module using proper ESD (Electrostatic Discharge) protection practices to prevent damage to internal circuitry.
  • Verify that all field wiring is connected via the specified dedicated cabling (KS8/AKB335) to maintain signal isolation and accuracy.
  • Ensure the module is fully seated in the backplane to ensure proper electrical contact.
  • Keep signal wiring separated from high-voltage power cables to minimize EMI/RFI interference.

FAQ

What type of RTD sensors are supported by the AAR145-S00?

The module supports 3-wire Pt100 RTDs compliant with JIS C1604:1997 and IEC751:1995 standards.

Can I mix RTD and Potentiometer inputs on the same module?

Yes, the AAR145 allows for individual selection of RTD or POT signal types for each of the 16 channels.

What is the required cable for this module?

The module requires the dedicated KS8/AKB335 cable for external field connections.