Skip to product information
1 of 3

5501-376 Analog I/O Module Woodward

5501-376 Analog I/O Module Woodward

Configured for high-speed signal processing and control loop interfacing in industrial automation platforms, the Woodward 5501-376 (5501-376 Analog I/O Module) provides direct physical/electrical execution. The module processes 8 channels of...

21 people are viewing this right now

AvailabilityLow stock: 6 left

SKU: 5501-376
Vendor: Woodward
Category: Analog I/O Module

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Configured for high-speed signal processing and control loop interfacing in industrial automation platforms, the Woodward 5501-376 (5501-376 Analog I/O Module) provides direct physical/electrical execution. The module processes 8 channels of 4-20 mA inputs and converts frequency inputs spanning 100 - 25,000 Hz into discrete 0-10 V voltage outputs across an RS-485 serial communication bus, maintaining an update cycle of 5 ms and galavanic isolation up to 500 Vrms.

Hardware Specifications

Parameter Specification
Model 5501-376
Brand Woodward
Origin USA
Weight 0.85kg
Dimensions Standard Woodward Rack / Din-Rail Layout
Operating Temp -40 deg C to +85 deg C
Power Consumption <= 15 W
Operating Voltage 24 VDC
Number of Channels 8
Input Range 4-20 mA
Input Frequency 100 - 25,000 Hz
Input Amplitude 1-25 Vrms
Input Impedance 2000 Ohms
Output Type Voltage (0-10 V)
Communication Interface RS-485
Resolution 12 bits minimum
Accuracy 0.03% full scale (software calibrated)
Isolation Voltage 500 Vrms
Update Time 5 ms

Actuator Loop Feedback Response Dynamics

The module integrates specialized signal processing routines designed to maintain rapid actuator loop feedback response within governor and drive control architectures. By executing high-speed analog acquisition alongside frequency input decoding (100 - 25,000 Hz) at a 5 ms update rate, the module minimizes phase lag during transient load changes. Digital filtering algorithms process raw sensor waveforms (1-25 Vrms amplitude) into 12-bit resolved numerical data, preventing actuator hunting and maintaining loop stability across fluctuating operating conditions.

Frequently Asked Questions

Q: How does the module handle ground loops and electrical interference across analog channels?

A: The board features 500 Vrms galvanic isolation between the internal processing logic and field side terminals, preventing common-mode noise and ground potential differences from corrupting input signal accuracy.

Q: What is the required bus termination standard for the onboard RS-485 interface?

A: The RS-485 differential line requires a 120 Ohm termination resistor placed across the physical signal pair at both extreme ends of the network trunk to eliminate line reflections during high-baud data transmission.

Q: Can the input channels accept high-frequency speed sensor signals directly?

A: Yes, the module accepts frequency inputs ranging from 100 to 25,000 Hz with amplitudes between 1 and 25 Vrms, processing these waveforms directly without external signal conditioning circuitry.

Field Installation Guidelines

  1. Mount the module chassis securely onto the designated DIN-rail or rack frame inside a sealed industrial enclosure rated IP54 or higher.
  2. Route 24 VDC primary power wiring using twisted, shielded 18 AWG copper conductors to minimize voltage drop across the supply terminals.
  3. Ensure all 4-20 mA and 0-10 V analog signal cables use individually shielded twisted pairs. Connect the cable drain wires to the main system earth ground terminal at one end only.
  4. Maintain a physical separation distance of at least 200 mm between low-voltage signal cables and high-voltage power lines inside cable trunks.
  5. Verify that RS-485 signal wires are wired in a daisy-chain topology with appropriate end-of-line termination before applying 24 VDC power.