The Allen-Bradley 2711-B5A3L3 is a PanelView 550 operator interface terminal designed for rugged industrial environments. This unit provides a robust human-machine interface (HMI) for real-time process monitoring, alarm logging, and...

18 people are viewing this right now

AvailabilityLow stock: 8 left

SKU: 2711-B5A3L3
Vendor: Allen-Bradley

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Description

The Allen-Bradley 2711-B5A3L3 is a PanelView 550 operator interface terminal designed for rugged industrial environments. This unit provides a robust human-machine interface (HMI) for real-time process monitoring, alarm logging, and manual control inputs. It communicates directly with programmable logic controllers (PLCs) to facilitate data exchange and system management. Built for demanding applications such as chemical processing, water treatment, and food packaging, this terminal features a durable design that minimizes downtime and ensures reliable operation in harsh conditions.

Features

  • Hybrid input system featuring both an analog resistive touchscreen (128 active cells) and a 10-key mechanical function keypad.
  • 5.5-inch monochrome blue-mode LCD display with 256 x 128 pixel resolution.
  • Integrated DH-485 communication port for seamless connectivity with SLC 500 and MicroLogix controller architectures.
  • Dedicated RS-232 serial port for local printer data logging.
  • Non-volatile memory storage with support for external ATA memory cards.
  • Long-life LED backlight rated for 100,000 hours of operation.
  • Battery-backed real-time clock for accurate event timestamping.

Applications

This operator terminal is suitable for a wide range of industrial automation tasks, including:

  • Process monitoring in petroleum and chemical refineries.
  • Machine control in food and beverage packaging lines.
  • System status visualization for water and wastewater treatment facilities.
  • Local operator control and data logging for PLC-based automation systems.

Technical Specifications

Model 2711-B5A3L3
Display Size 5.5 inches
Display Type Monochrome LCD (Blue Mode)
Input Method Keypad and Touchscreen
Communication DH-485 and RS-232
Memory 170 KB runtime / 240 KB non-volatile
Power Supply 24 VDC
Operating Temperature 0 to 55 deg C
Enclosure Rating NEMA 12/13, 4X (Indoor), IP54/IP65
Vibration Rating 2 g at 2000 Hz

Installation Guidelines

  • Ensure the terminal is mounted in a panel or enclosure that meets NEMA 4X/12/13 or IP65 requirements to maintain environmental protection.
  • Verify that the power supply is a stable 24 VDC source before connection.
  • Use shielded communication cables for the DH-485 network to minimize EMI interference in high-noise environments.
  • Always power down the system before inserting or removing the ATA memory card or performing maintenance.
  • Ensure adequate ventilation around the unit to maintain operating temperatures within the 0 to 55 deg C range.
  • Handle with care to avoid damage to the touchscreen overlay; use only appropriate tools or finger-touch for operation.

FAQ

Is this unit still in production?

No, the 2711-B5A3L3 is classified as a discontinued or obsolete product by the manufacturer. We provide these units as refurbished or surplus stock to support legacy systems.

What is the primary communication protocol used?

This terminal utilizes the DH-485 proprietary network protocol for communication with Allen-Bradley SLC 500 and MicroLogix controllers.

Can I replace the backlight?

Yes, the backlight is replaceable. The compatible replacement module is the 2711-NL1.