ALR121-S53 YOKOGAWA Communication Module | New & Original Stock

Configured for serial data exchange between Field Control Stations (FCS) and peripheral subsystems, the YOKOGAWA ALR121-S53 (ALR121-S53 Communication Module) provides direct physical signal processing and protocol management. This hardware component...

20 people are viewing this right now

AvailabilityLow stock: 99 left

SKU: ALR121-S53
Vendor: Yokogawa
Related Series:

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Configured for serial data exchange between Field Control Stations (FCS) and peripheral subsystems, the YOKOGAWA ALR121-S53 (ALR121-S53 Communication Module) provides direct physical signal processing and protocol management. This hardware component serves as the interface bridge utilized to execute half-duplex RS-422/RS-485 communication across distributed industrial control network architectures.

Hardware Specifications

Parameter Specification
Model ALR121-S53
Brand YOKOGAWA
Origin Subject to factory marking
Weight 0.3 kg
Dimensions Not specified
Operating Temp Industrial standard range
Current Consumption 0.5 A
Interface RS-422/RS-485
Transmission Speed 1200 to 38400 bps
Transmission Method Half-duplex, Start-stop sync

Serial Communication and Data Integrity

The ALR121-S53 supports versatile serial integration, allowing the FCS to interface with subsystems like FA-M3 controllers. The module manages frame synchronization and parity checking to ensure data packets are correctly reconstructed during transfer. By utilizing RS-485 signaling, the module enables robust multi-drop communication over distances reaching 1200 meters, which is essential for remote subsystem monitoring. The implementation of ASCII or Binary transmission codes provides flexibility for diverse communication protocols, while the galvanically isolated interface stage mitigates noise and ground loops in harsh industrial electrical environments.

Frequently Asked Questions (FAQ)

Q: Can the ALR121-S53 operate in full-duplex mode?

A: No. The ALR121-S53 is designed strictly for half-duplex communication. Ensure the connected subsystem protocol is configured for polling or master-slave command sequences compatible with half-duplex timing.

Q: Is the transmission speed configurable via software?

A: Yes. Transmission parameters, including baud rate, parity, and character format, are configured within the engineering station settings for the corresponding FCS slot. Ensure settings match the requirements of the slave device to prevent framing errors.

Field Installation Guidelines

  • Bus Termination: For RS-485 networks, ensure the bus is terminated with a 120-ohm resistor at both extreme ends of the physical segment to prevent signal reflections. Improper termination is the primary cause of intermittent data corruption in long-distance serial links.
  • Shielding and Grounding: Utilize high-quality twisted-pair, shielded cabling for all serial connections. Terminate the shield at a single, verified system ground point. Do not ground the shield at both ends, as this can create ground loops that introduce noise into the communication signals.
  • Mounting Protocol: The module is designed for installation in various field control units such as AFV30 or ANB10 series. Ensure the module is firmly seated in the backplane connector and that all retention clips are fully engaged to withstand vibration.
  • Cable Routing: Maintain a minimum distance of 300 mm from high-voltage power cables or VFD output wiring to avoid electromagnetic interference (EMI) that could compromise the serial data transmission integrity.