Skip to product information
1 of 3

Bently Nevada 330191-00-33-90-05 3300 XL 8 mm ETR Proximity Probe

Bently Nevada 330191-00-33-90-05 3300 XL 8 mm ETR Proximity Probe

The Bently Nevada 330191-00-33-90-05 is a high-performance 3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probe. Designed for demanding industrial environments, this probe provides reliable, non-contact measurement of static...

19 people are viewing this right now

AvailabilityLow stock: 8 left

SKU: 330191-00-33-90-05
Vendor: Bently Nevada
Category: Proximity Probe

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

The Bently Nevada 330191-00-33-90-05 is a high-performance 3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probe. Designed for demanding industrial environments, this probe provides reliable, non-contact measurement of static and dynamic distances between the probe tip and a conductive target. It is essential for monitoring radial vibration, axial position, and speed in critical rotating machinery.

Features

  • Extended Temperature Range (ETR): Engineered to maintain accuracy and integrity under significant thermal stress.
  • 8 mm Tip Diameter: Industry-standard sensing element for consistent eddy current signal generation.
  • Integrated 9.0 Meter Cable: Reduces the need for intermediate connections, minimizing signal noise and potential failure points in harsh environments.
  • ClickLoc Connector: Features a tactile locking mechanism to ensure a secure, sealed connection, preventing fluid ingress.
  • Rugged Construction: Built with a 3/8-24 UNF thread for secure mounting in specialized housings.

Applications

  • Gas Turbines: Monitoring exhaust vibration, bearing struts, and seal clearance.
  • Steam Turbines: Measuring thrust position and differential expansion near labyrinth seals.
  • Centrifugal Compressors: Detecting high-speed shaft vibration and eccentricity.
  • Hydroelectric Turbines: Tracking generator radial vibration and overall health.
  • Industrial Motors: Identifying rotor imbalance and bearing abnormalities.

Technical Specifications

Model 330191-00-33-90-05
Probe Type 3300 XL 8 mm ETR Proximity Probe
Thread Size 3/8-24 UNF
Unthreaded Length 0.0 in
Case Length 3.3 in
Cable Length 9.0 meters (29.5 feet)
Agency Approvals CSA, ATEX, IECEx
Target Material Standard calibration for AISI 4140 steel

Installation Guidelines

  • ESD Precautions: Handle the probe with care to prevent electrostatic discharge damage to the internal electronics.
  • Mounting: Ensure the probe is mounted in a rigid bracket to prevent mechanical resonance. Use the provided lock nuts to secure the 3/8-24 thread.
  • Gap Setting: The ideal operating gap is typically 1.27 mm (50 mils), corresponding to a -9.0 Vdc output when measured between the SIG and COM terminals of the associated Proximitor sensor.
  • Cable Routing: Route the integrated 9.0m cable away from high-voltage power lines and sources of high EMI to maintain signal integrity.
  • Connector Handling: The ClickLoc connector should be tightened by hand until a tactile click is felt; do not use pliers or excessive force.

FAQs

What is the primary function of the 330191-00-33-90-05?

This probe measures the distance between the sensor tip and a conductive target, allowing for the monitoring of vibration, position, and speed in fluid-film bearing machines.

What does the 05 suffix represent?

The 05 suffix indicates that the unit meets specific agency certifications, including CSA, ATEX, and IECEx, making it suitable for hazardous area installations.

Can this probe be used with any shaft material?

The standard calibration is optimized for AISI 4140 steel. If the target material differs, the scale factor must be adjusted accordingly.

How do I verify the probe is installed correctly?

Use a digital voltmeter to measure the output voltage at the Proximitor sensor terminals. A reading of -9.0 Vdc is the standard target for a 1.27 mm (50 mil) gap.