Skip to product information
1 of 3

Bently Nevada 991-06-50-01-00 Thrust Transmitter

Bently Nevada 991-06-50-01-00 Thrust Transmitter

The Bently Nevada 991-06-50-01-00 is a dedicated thrust transmitter designed for continuous monitoring of axial position in rotating machinery. This unit provides a reliable 4-20 mA output proportional to the...

29 people are viewing this right now

AvailabilityLow stock: 8 left

SKU: 991-06-50-01-00
Vendor: Bently Nevada
Category: Thrust Transmitter

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

The Bently Nevada 991-06-50-01-00 is a dedicated thrust transmitter designed for continuous monitoring of axial position in rotating machinery. This unit provides a reliable 4-20 mA output proportional to the measured thrust displacement, facilitating integration into PLC, DCS, or SCADA systems for machinery protection and condition monitoring.

Features

  • Provides a linear 4-20 mA output proportional to the thrust position.
  • Features non-interacting external adjustments for zero and span, allowing for precise calibration without disrupting the loop.
  • Designed for standard industrial mounting using 35 mm DIN-rail clips.
  • Includes current limiting circuitry to protect the loop and connected instrumentation.
  • Compatible with standard proximity probe systems for accurate non-contact displacement measurement.

Applications

  • Axial position monitoring for centrifugal compressors, turbines, and pumps.
  • Integration into plant-wide machinery protection systems.
  • Retrofitting legacy monitoring loops with modern 4-20 mA transmitter technology.

Technical Specifications

Product Model 991-06-50-01-00
Measurement Range 0.6 to -0.6 mm
Cable Length 5.0 meters (16.4 feet)
Mounting 35 mm DIN-rail
Maximum Loop Resistance 1,000 Ohm (including cable at 35 Vdc)
Current Limiting 23 mA typical
Minimum Target Size 9.5 mm (0.375 in) diameter

Installation Guidelines

  • Ensure the transmitter is mounted in a clean, dry, and vibration-isolated environment.
  • Use shielded twisted-pair cabling for the 4-20 mA loop to minimize electromagnetic interference (EMI).
  • Verify that the proximity probe target area meets the minimum diameter requirement of 9.5 mm to ensure measurement accuracy.
  • Power down the loop before making any wiring connections or adjustments to the transmitter terminals.
  • Ensure proper grounding of the cable shield at the control system end to prevent ground loops.

FAQ

What is the primary function of the 991-06-50-01-00?
This device acts as a signal converter, taking input from a proximity probe and outputting a 4-20 mA signal that represents the axial thrust position of a machine shaft.

Can the zero and span be adjusted?
Yes, the unit features non-interacting external adjustments, allowing you to calibrate the transmitter output without affecting the zero setting.