Digital Indicating Controller YOKOGAWA UT55A-040-11-00/LP

Digital Indicating Controller YOKOGAWA UT55A-040-11-00/LP

Configured for precision temperature and process loop management, the YOKOGAWA UT55A-040-11 (UT55A-040-11-00/LP Digital Indicating Controller) provides direct signal processing and setpoint control across distributed instrumentation networks.

Suffix Breakdown & Model...

15 people are viewing this right now

AvailabilityIn stock

SKU: UT55A-040-11-00/LP
Vendor: Yokogawa

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Configured for precision temperature and process loop management, the YOKOGAWA UT55A-040-11 (UT55A-040-11-00/LP Digital Indicating Controller) provides direct signal processing and setpoint control across distributed instrumentation networks.

Suffix Breakdown & Model Matrix

  • UT55A: Base model for 1/4 DIN digital indicating controller.
  • -040: Specifies hardware configuration including standard control outputs and remote auxiliary analog input support.
  • -11: Defines internal I/O mapping and power supply voltage interface.
  • -00/LP: Designates standard bezel finish and factory software/logic customization level.

Hardware Specifications

Parameter Specification
Model UT55A-040-11-00/LP
Brand YOKOGAWA
Origin Japan
Weight 1.12kg
Dimensions 1/4 DIN standard form factor
Operating Temp Not specified
Power Consumption 18 VA
Supply Voltage 100-240 VAC, 50/60 Hz
Display 5-digit LCD
Input Configuration Remote auxiliary analog input + 1 digital input

Process Control Instrumentation Connectivity

The controller integrates seamlessly into standard process environments utilizing 4-20 mA HART loop protocol standards for field device communication. It features channel-to-channel isolation to ensure that thermocouple or RTD inputs are protected from common-mode voltage interference. The internal circuitry provides advanced cold junction compensation (CJC) to maintain high-accuracy readings in variable ambient temperature conditions, ensuring stable setpoint execution within DCS instrumentation loops.

Frequently Asked Questions

Q: Does the UT55A support field calibration of the analog inputs?

A: Yes, the unit allows for software-based calibration offsets to correct for sensor lead resistance or thermocouple inaccuracies, provided the controller is in the appropriate configuration mode.

Q: Can this model be integrated into an existing Profibus or Fieldbus network?

A: The base model listed utilizes standard analog/digital I/O; integration into digital fieldbus networks typically requires a specific communication module variant or gateway interface.

Field Installation Guidelines

  • Verify the 1/4 DIN cutout dimensions on the control panel to ensure a secure mechanical fit and effective seal for the bezel.
  • Use shielded, twisted-pair cabling for all analog input signals to minimize electromagnetic interference (EMI) and signal noise.
  • Ensure the 100-240 VAC power source is stable and isolated from large inductive loads, such as contactors or motors, to prevent voltage transients.
  • Terminate all sensor leads according to the wiring diagram on the housing to avoid ground loops, particularly when using grounded thermocouples.
  • Confirm that the auxiliary analog input is configured for the correct signal range (voltage or current) in the software menu before applying process signals.