Genuine Automation Parts | Worldwide Express Delivery | 12-Month Warranty — [GET A QUOTE]

The FC-SAI-1620M is a high-integrity analog input module for the Honeywell Safety Manager (SMS) system. With 16 input channels, it processes critical sensor data from field instruments such as pressure transmitters, flow meters, and level sensors.
Designed for SIL 2 and SIL 3 applications, the module features fault-tolerant circuitry and extensive internal diagnostics to ensure signal accuracy and system reliability.
| Specification | Details |
|---|---|
| Model Number | FC-SAI-1620M |
| Component Type | Safety Analog Input Module |
| Channel Density | 16 Input Channels |
| Signal Type | 4–20 mA analog signals |
| Module Architecture | 1-out-of-2 (1oo2) internal voting with advanced diagnostics |
| Conversion Resolution | High-precision A/D conversion for safety-critical loops |
| Physical Dimensions | 12.7 × 12.7 × 12.7 cm |
| Net Weight | 0.8 kg |
| Environmental Rating | Industrial coating for corrosion protection |
| System Compatibility | Honeywell Safety Manager / SMS |
The FC-SAI-1620M continuously monitors for hardware faults and field wiring issues (open/short circuits). Self-tests on conversion circuits and reference voltages detect discrepancies, which are reported to the Safety Manager controller for controlled response or fail-safe shutdown.
The “M” designation indicates a specific hardware revision with conformal coating suitable for demanding industrial environments.
Q: Does the FC-SAI-1620M support HART communication?
A: No, it is optimized for high-speed safety analog inputs. HART diagnostics require Honeywell field termination assemblies or specialized HART multiplexers.
Q: Can the FC-SAI-1620M be hot-swapped?
A: Yes, in a redundant Safety Manager configuration, it can be replaced while the system is energized if the redundant partner module is healthy.