Skip to product information
1 of 3

RTD Analog Input Module Emerson DeltaV KJ3002X1-BF1

RTD Analog Input Module Emerson DeltaV KJ3002X1-BF1

Product Description

The KJ3002X1-BF1 (Assembly Number 12P0554X122) is a high-performance Resistance Temperature Detector (RTD) input module integrated into the Emerson DeltaV M-Series I/O family. This module is engineered to interface...

20 people are viewing this right now

AvailabilityLow stock: 99 left

SKU: KJ3002X1-BF1
Vendor: Emerson

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Product Description

The KJ3002X1-BF1 (Assembly Number 12P0554X122) is a high-performance Resistance Temperature Detector (RTD) input module integrated into the Emerson DeltaV M-Series I/O family. This module is engineered to interface directly with 2-wire, 3-wire, or 4-wire RTD sensors, converting low-level resistance signals into digital process variables. It features high-resolution analog-to-digital conversion and onboard cold-junction compensation to maintain measurement accuracy across fluctuating ambient temperatures.

Technical Specifications

Specification Details
Channel Density 8 independent RTD input channels
Input Type Support Pt100, Pt200, Pt500, Ni100, Ni120, and Cu10 sensors
Resistance Range 0 to 2000 Ohms (covering standard industrial ranges)
Accuracy ±0.1% of span at calibrated temperature
Resolution 16-bit A/D converter performance
Common Mode Rejection >100 dB at 50/60 Hz
Local Bus Power 12V DC at 150 mA maximum
Physical Dimensions 4.4 cm x 10.2 cm x 10.8 cm
Weight 0.2 kg

Operational Integration

The KJ3002X1-BF1 is designed for high-availability environments, supporting online removal and insertion (hot-swapping) under power. It automatically performs self-diagnostics and reports sensor burnout or short-circuit faults to the DeltaV controller, reducing troubleshooting time in critical thermal loops.

Engineering FAQ

Q: Does the KJ3002X1-BF1 support lead-wire resistance compensation?
A: Yes, for 3-wire and 4-wire RTD configurations, the module actively compensates for lead-wire resistance to ensure that cable length does not introduce measurement error.