Schneider Electric TM2AMI8HT Modicon M238 Analog Input Module

Schneider Electric TM2AMI8HT Modicon M238 Analog Input Module

Description

The Schneider Electric TM2AMI8HT is a high-density analog input module engineered for the Modicon M238 PLC platform. This module provides 8 independent differential input channels designed to interface with various...

24 people are viewing this right now

AvailabilityLow stock: 9 left

SKU: TM2AMI8HT
Vendor: Schneider

Shipping & Returns

Reliable Worldwide Delivery

  • Carriers: Shipped via DHL, FedEx, UPS, or USPS.
  • Dispatch: Orders processed in 1-2 business days and dispatched within 3-5 business days.
  • Tracking: Full tracking details provided via email upon shipment.

30-Day Money-Back Guarantee

  • Guarantee: 30-day return window for in-stock, factory-sealed products.
  • Condition: Items must be unopened, unused, and in original packaging.
  • Authenticity: We guarantee 100% original and authentic hardware.

Need more details? Read our fullShipping PolicyandRefund Policy.

Authenticity & Warranty

  • Genuine Guarantee: We supply only 100% original, brand-new, and factory-sealed industrial automation parts.
  • Full Coverage: Every component is backed by a 12-month comprehensive warranty from the date of purchase.
  • Traceability: All products come with original factory documentation and accessories for full industrial compliance.

Technical Support & Sourcing

  • Expert Assistance: Our technical team provides free consultation to help you verify compatibility for DCS and PLC systems.
  • Rare Part Sourcing: Specializing in obsolete and hard-to-find components from Allen-Bradley, Siemens, ABB, HIMA, and more.
  • Bulk Inquiries: Contact us at pambo@5gplc.com for volume pricing or customized project quotes.
View full product details

Description

The Schneider Electric TM2AMI8HT is a high-density analog input module engineered for the Modicon M238 PLC platform. This module provides 8 independent differential input channels designed to interface with various industrial sensors and transmitters. It performs high-precision signal conversion, transforming analog physical variables into digital data with 11-bit plus sign resolution. The module is built for demanding industrial environments, ensuring signal integrity through integrated noise filtering and robust channel isolation, which helps maintain consistent process control and reduces the risk of unexpected system downtime.

Features

  • 8 independent differential analog input channels for flexible sensor integration.
  • Configurable input ranges including 0-10 V, -10 to +10 V, 0-20 mA, and 4-20 mA.
  • High-speed data acquisition with a sampling rate of 10 ms per channel.
  • Integrated 500 V AC isolation between analog inputs and internal logic circuits to prevent ground loops and electrical interference.
  • Compact design with a removable screw terminal block for efficient wiring and maintenance.
  • Direct expansion bus connectivity for seamless integration with the M238 controller.

Applications

The TM2AMI8HT is suitable for a wide range of continuous manufacturing and process control applications, including thermal power generation, oil and gas refining, chemical processing, and mining operations. It is ideal for monitoring pressure, flow, temperature, and level transmitters that require high-accuracy analog-to-digital conversion.

Technical Specifications

Model TM2AMI8HT
Brand Schneider Electric
Input Channels 8 Differential
Resolution 11 bits + sign
Input Ranges 0-10 V, -10/+10 V, 0-20 mA, 4-20 mA
Sampling Time 10 ms per channel + 1 scan time
Isolation 500 V AC (Channel to Logic)
Internal Consumption 60 mA at 5 VDC
External Consumption 55 mA at 24 VDC
Operating Temperature -10 to 55 deg C

Installation Guidelines

  • Ensure the PLC system is powered down before installing or removing the module from the expansion bus.
  • Mount the module on a standard DIN rail, ensuring proper alignment with adjacent modules to maintain bus connectivity.
  • Use shielded twisted-pair cabling for all analog signals to minimize electromagnetic interference (EMI).
  • Connect the cable shields to a common earth ground at the source or the module entry point as per standard industrial grounding practices.
  • Verify that external 24 VDC power is correctly wired to the terminal block to support active current loop sensors.
  • Keep signal wiring separated from high-voltage AC power lines to prevent signal noise and potential damage to the input circuitry.

FAQ

What is the resolution of the TM2AMI8HT module?
The module provides 11-bit plus sign resolution, resulting in a total of 12 bits of data for each analog input channel.

Does this module require external power?
Yes, the module requires 24 VDC external power for operation, in addition to the 5 VDC power supplied by the internal controller bus.

Can I use this module for both voltage and current inputs?
Yes, the module is software-configurable to support 0-10 V, -10 to +10 V, 0-20 mA, and 4-20 mA signal types.